Chapter 3. Operation
3-18
DATA RATE
Selects the data rate for the control port. This should be
consistent with all units on a chain and with the modem
and/or PC/Proxy Agent serial port.
Choices: 1200, 2400, 9600

2) ALARMS

Used to initialize the method by which the control port
handles alarm conditions.
TRAPS
This setting determines if alarm conditions should
automatically send alarm messages (traps) to the controlling
PC/Proxy Agent. The setting is for this unit, or for slaves if
this unit is a master.
Choices: ENAB - Enable; DISA - Disable
OUTPUT
Selects whether the alarm traps (if enabled) are sent directly,
or if the telephone number stored in the TSU should be
dialed first (industry-standard AT dial command sent to
modem).
Choices: DIRECT or DIAL
TEL NUM
This is the telephone number which is dialed to obtain alarm
traps. The string can be up to 20 characters in length and is
terminated with a semi colon (;) as the last character. A colon
(:) character is used to represent a pause in the dial string.
Example: For number 9:5551212; dial 9, pause, and then send
5551212. This pause could be effected to access an outside
line form a PBX, etc.
When editing a specific character, the scroll keys are used to
scroll from 0 to 9, then ":" and ";". The new telephone
number is entered into the TSU only upon pressing ENTER
after typing the ";".
Choices: 20 digits (0-9, : and ;)