CONTENTS
1. GENERAL .................................................................. 1
2. INSTALLATION ....................................................... 5
3. OPERATION .............................................................. 8
4. PRODUCT SPECIFICATIONS .............................. 14
FIGURES
Figure 1. T1 Nx64 HTU-R ............................................ 1
Pair Deployment ............................................ 2
Figure 5. HTU-C Rear Panel ........................................ 3
Figure 7. Introductory Menu Screen ........................... 10
Figure 8. HDSL Main Menu Screen ........................... 10
Figure 10. Loopback Options Screen ........................... 12
Figure 11. Self-Test Options Screen ............................. 12
Figure 12. Provisioning Options Screen ....................... 13
Figure 13. Troubleshooting Screen ............................... 13
TABLES
Table 1. Front Panel LED Indicators ............................. 4
Unit ................................................................... 5
Assignments ..................................................... 6
Table 4. V.35 Signal Designations ................................. 7
Table 5. Screen Abbreviations ....................................... 9
Table 6. Product Specifications .................................... 14
A. The Nx64 HTU-R can be used in a variety of environments. When using this equipment, follow these basic
safety precautions to reduce the risk of fire, electric shock and personal injury:
1. Do not use this product near water (for example, near a bathtub, washbowl, sink, or laundry tub, in
a wet basement or near a swimming pool).
2. Avoid using this or other telephone equipment (other than the cordless type) during an electrical
storm.
3. Do not use the telephone to report a gas leak in the vicinity of the leak.
4. Use only the power cord, power supply and/or batteries indicated in this document. Do not dispose
of batteries in a fire; check with local codes for possible special disposal instructions.
61245023L1-5B
T1 Nx64 HTU-R
Installation and Maintenance

1. GENERAL

Functional Overview
The ADTRAN T1 Nx64 HTU-R is a network
terminating unit which uses High-bit-rate Digital
Subscriber Line (HDSL) technology to transport T1
data over copper loops. Each loop operates over a
single pair of copper wire and carries half of the
total bandwidth along with a small amount of
overhead for maintenance and performance
monitoring functions. Figure 1 is an illustration of
the T1 Nx64 HTU-R.
The T1 Nx64 HTU-R is a standalone unit which
contains an integrated Data Service Unit (DSU).
This eliminates the need for a separate DSU. The
T1 Nx64 HTU-R provides Nx56 kbps or Nx64 kbps
data transmission capability. Possible data rates
range from 64 kbps to 1.536 Mbps and 56 kbps to
1.344 Mbps.
IMPORTANT
Section 61245023L1-5B, Issue 2
Section 61245023L1-5B
CLEI Code # T1L3DEDA_ _
T1 HTU-R
Figure 1. T1 Nx64 HTU-R
Issue 2, April 2000
1

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN T1 Nx64 HTU-R

  • Page 1: Table Of Contents

    Figure 13. Troubleshooting Screen ....... 13 the T1 Nx64 HTU-R. TABLES The T1 Nx64 HTU-R is a standalone unit which Table 1. Front Panel LED Indicators ......4 contains an integrated Data Service Unit (DSU). Table 2. Configuration Options for a Remote (Slave) This eliminates the need for a separate DSU.
  • Page 2: Figure 2. System Configuration For T1 Nx64 Htu-R Pair Deployment

    Figure 2. System Configuration for T1 Nx64 HTU-R Pair Deployment Network T1 HDSL (Remote) Remote T1 HTU-R Equipment HTU-C V.35 DSX-1 HDSL V.11 I/F Loops Figure 3. System Configuration for T1 Nx64 HTU-R Deployment with ADTRAN HTU-C Section 61245023L1-5B, Issue 2 61245023L1-5B...
  • Page 3: Figure 4. V.35 To Rs-449 Adapter Cable Pinout

    HTU Side (M34 Male) DTE Side (DB37 Female) Signal Name Signal Name Number Number Frame Ground Frame Ground Signal Ground Signal Ground Rx Common Tx Common Call Indicate TxD A TxD A RxD A RxD A TxD B TxD B RxD B RxD B Ext TxC A...
  • Page 4: Figure 1. T1 Nx64 Htu-R

    Off ....DTE is not ready to send or receive data Green .... DTE is ready to send and/or receive data Indicates that the T1 Nx64 HTU-R is ready to send Transmit and/or Receive Data HTU ....Off ....T1 Nx64 HTU-R is not ready to send or receive data Green ....
  • Page 5: Installation

    HTU-R Mode Selects between Master and Slave mode for the T1 Nx64 HTU-R Master (HTU-C) ... The T1 Nx64 HTU-R is configured as the Local (Master) unit Slave (HTU-R) ..... The T1 Nx64 HTU-R is configured as the Remote (Slave) unit...
  • Page 6: Table 3. T1 Nx64 Htu-R Hdsl Interface Pin

    Slave, follow Step 3 to properly configure the Master unit. If you are deploying the T1 Nx64 HTU-R as a remote unit in a circuit with Table 3. T1 Nx64 HTU-R HDSL Interface an ADTRAN T1 HTU-C, verify that the HTU-C is...
  • Page 7: Table 4. V.35 Signal Designations

    Slave, connect the HDSL interface cable for each 1 and Loop 2. unit. If you are deploying the T1 Nx64 HTU-R as a remote unit in a circuit with an ADTRAN A loop loss value of 27dB or less indicates proper T1 HTU-C, verify that the HTU-C is properly HDSL loop length.
  • Page 8: Operation

    Signal quality is a good 3. OPERATION indication of BER performance on either loop. Once the ADTRAN T1 Nx64 HTU-R is properly LOOP LOSS - This measurement provides a configured and installed, it should operate numeric indication of the HDSL signal attenuation.
  • Page 9: Table 5. Screen Abbreviations

    Insert Errors Feature Table 5. Screen Abbreviations This feature is located under the BERT Tests option Abbreviation Definition of the Test menu using the front panel LCD. This option is only valid if the Nx64 is already running AMI ...... Alternate Mark Inversion the Test Pattern.
  • Page 10: Figure 7. Introductory Menu Screen

    2[X] 1[X] 2[X] AT HTU-C AT HTU-R Press “M” to view Main Menu. Figure 7. Introductory Menu Screen ADTRAN HDSL MAIN MENU 1) CURRENT SYSTEM STATUS 2) PERFORMANCE HISTORY 3) ADTRAN INFORMATION 4) LOOPBACK OPTIONS 5) SELF-TEST 6) PROVISIONING 7) TROUBLESHOOTING Choose a screen by pressing the corresponding number.
  • Page 11: Figure 9. Current System Status Screen

    –7 0 or higher will support a BER of better than 10 appears in the center of the screen. ADTRAN defines the following as guidelines that LOSS ....Pulse Attenuation Measurement correspond to the operation of the NTU faceplate SYNC ....HDSL Loop 1 and Loop 2 Sync LEDs labeled LP1 and LP2.
  • Page 12: Figure 10. Loopback Options Screen

    The HDSL Loopback Options screen is illustrated in Figure 10. The Self-Test Options Screen is illustrated in Figure 11. Loopbacks and Self-Test may be evoked or terminated using these screens. A status of current loopback conditions is also provided. CURRENT SYSTEM STATUS LOOPBACK OPTIONS _____ _____...
  • Page 13: Figure 12. Provisioning Options Screen

    The Provisioning Options Screen is illustrated in The Troubleshooting Display Screen, illustrated in Figure 12. Provisioning may be viewed by the Figure 13, graphically depicts an HDSL circuit. HTU-C but may not be changed. Provisioning The unit reviews red, yellow, and blue alarm changes may only be implemented through the conditions in the circuit to automatically predict Nx64.
  • Page 14: Product Specifications

    5. WARRANTY AND CUSTOMER SERVICE 4. PRODUCT SPECIFICATIONS ADTRAN will replace or repair this product within Product specifications for the T1 Nx64 HTU-R are five years from the date of shipment if it does not detailed in Table 6. meet its published specifications or fails while in service.

Table of Contents