BRAMIDAN B3 Operating Instructions Manual page 40

Baler
Table of Contents

Advertisement

Check top switch (K)
Close doors (F) and (G) and press the green start button (B).
The pump station must stop when the platen (H) reaches the
top position.
It is recommended to activate the emergency stop (A) before
visually checking the top switch:
Check that the top switch (K) is intact and free from defects.
The arm must be able to move freely.
Deactivate the emergency stop button (A).
Reset the baler with a single push of the green start button
(B).
Check the door switch (L)
Run the platen down to the lowest position by pressing the
orange finish indicator button (C).
Open door (F) and activate two-hand operation (C) and (D).
The press must not eject the bale.
Open door (G) and check that the door switch (L) is complete
and not defective. It should be possible to press the roll in and
out / The arm must be able to move freely.
Check the closing system on door (F)
Open door (F) and check that the closing system works
correctly.
Check the closing system on door (G)
Open doors (F) and (G) and check that the closing system
and spindle (handwheel) work correctly.
Check hydraulics
Check hydraulic hoses for cracks and ageing.
There must be no leaks from either the cylinders, fittings, or
the pump station.
Applicable for machine number: ____________________________________
Safety check carried out on ________________________________________
Signature: _______________________________________________________
Baler B3 and B4
Defect
Defect
Defect
Defect
Defect
16 Tjekliste for sikkerhedstjek USA.fm • Page 36
OK
OK
OK
OK
OK

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B4

Table of Contents