The Bale Press Cannot Eject The Bale; Leakage - BRAMIDAN B3 Operating Instructions Manual

Baler
Table of Contents

Advertisement

The baler is unable to eject the bale:
Is the two-hand control not responding?
Has the emergency stop been activated?
Has the top switch been activated?
Is a foreign object trapped in the ejection
system?
Is the strap installed incorrectly?
Is the steel wire installed incorrectly?

Leakage:

Is hydraulic oil leaking from the baler?
Baler
Two-hand control requires a simultaneous
constant pressure within a time interval of ½
second.
Release the emergency stop.
Remove any trapped material at the top
switch.
Remove the foreign object.
Cut the strap and tip the bale out of the
chamber. Press the bale again.
Clip the steel wire and tip the bale out of the
chamber. Press the bale again.
Disconnect the power to the baler. Wipe up
the oil, using a cleanser designed for
hydraulic oil if necessary. Repair the leak
before the baler is put into use.