8 Operating principles

Power interruption:

If power to the bale presser has been disconnected, the baler must be reset with a single push of
the green start button. If this occurs during ejection of the bale, continue the process by pressing
the two orange finish indicator buttons, which together constitute two-hand control. The buttons
only light while being pressed.

Emergency stop:

If the emergency stop has been activated, it must be deactivated, after which the baler must be
reset with a single push of the green start button.
Start button:
In order to activate the start button between each press cycle, the filling door must be opened
and closed. This is due to the door switch's monitoring of the baler, and prevents intentional
evasion of the safety system.

Two-hand control:

The two-hand control requires a simultaneous, constant pressure within a time interval of ½
second.
The bale ejection is blocked:
There must not be any materials jammed in the ejection system, since this will prevent the press
from ejecting the bale. The ejection mechanism on the platen must be pushed completely
forward, if it is pushed back, the jammed material must first be removed.