15 Troubleshooting

If it is not possible to solve the problems using the troubleshooting table, or there are any other
questions, contact the dealer.
The baler is unable to start:
Is the baler connected to the supply network?
Is the repair switch set to "0" or OFF?
Has the emergency stop been activated?
The baler cannot start and the start button
is flashing:
One flash, the door switch is reporting errors.
Two flashes, the emergency stop is activated.
Three flashes, the oil temperature is too high.
Four flashes, the motor temperature is too
high.
Five flashes, service is recommended.
Six flashes, other serious errors.
The baler is very noisy:
Have one or more of the platen's wear blocks
worn away?
Is the platen's release roller worn?
Is a foreign object trapped between the
platen and the chamber?
Baler
(Hereafter called the "strap")
Connect the cable to the supply network.
Set the repair switch to "1" or "ON".
Release the emergency stop.
The filling door must be opened between
each press cycle.
Open and close the door completely.
Release the emergency stop.
Wait for the temperature to be normalized,
which can take a couple hours. (If the
problem is recurring, call for service).
Wait for the temperature to be normalized,
which can take a couple hours. (If the
problem is recurring, call for service).
Order a service from the dealer.
Contact the dealer.
Replace the wear blocks.
Replace the release roller.
Remove the foreign object.
15 Fejlfinding USA.fm • Page 32