Installation As A System Solution In The Stainless Steel Enclosure "Exclusive Ii - Bartec POLARIS Remote KVM Analog Series User Manual

15" / 19.1"
Table of Contents

Advertisement

POLARIS REMOTE
- for Zone 1/21
POLARIS Remote KVM Analog 15" / 19.1"
6.2.2

Installation as a system solution in the stainless steel enclosure "Exclusive II"

Technical data subject to change.
08/2019
The POLARIS is available as a ready-made system solution in a stainless steel enclosure
e.g. "Exclusive II" for floor, wall or table mounting.
CSA approval
The CSA approval for the POLARIS series includes an POLARIS system solution in
stainless steel enclosure "Exclusive II" for wall and floor mounting.
Other system solutions and mounting systems (e.g. table mounting) have not been
tested and approved in accordance with CSA.
For POLARIS built into the enclosure door
The open door must be supported and secured during the installation and servicing
phase. Otherwise the wall thickness specified may lead to the door sagging slightly
when open.
Selection of location
CAUTION
Pay attention to wall and ground condition!
A sufficiently stable wall (e.g. concrete or limestone) or floor (e.g. concrete) must
be selected for securing the load-bearing system.
The structural stability of the wall or floor must be able to bear 4 times the weight of
the POLARIS as system solution.
The support arm system must be assembled using suitable mounting materials
(M12) (e.g. dowels or stud bolts).
Work steps (Stainless steel enclosure "Exclusive II")
(1)
Prepare supply and data line(s).
(2)
Prepare installation on the basis of the drilling template (see illustration 7 - 9).
(3)
Install supply and data line(s) in the base.
(4)
Fasten the supporting system.
(5)
Pull supply and data line(s) through the cable glands provided into the enclosure.
Ensure there is sufficient length.
(6)
Mount the enclosure on the supporting system.
(7)
Open the terminal compartments on the POLARIS and feed the supply and data
line(s) through the cable glands and wire them. Block unused terminal
compartments with a blanking plug.
(8)
Close the door of the "Exclusive II" enclosure.
Installation
EN 21/48