Explosion protection and
approvals
3.

Explosion protection and approvals

EN 8/48
POLARIS REMOTE
- for Zone 1/21
POLARIS Remote KVM Analog 15" / 19.1"
POLARIS Remote KVM Analog
Type 17-71V2-....
ATEX
Ex protection type
Certification
Standards in accordance with
EMC Directive 2014/34/EU
IECEx
Ex protection type
Certification
Standards in accordance with
EMC Directive 2014/34/EU
Special conditions
II 2G Ex db eb mb q [ib op pr] IIC T4 Gb
II 2D Ex mb tb IIIC T120°C Db
-20 °C ≤ Ta ≤ 60 °C
IBExU 05 ATEX 1117 X
EN 60079-0:2012+A11:2013
EN 60079-1:2014
EN 60079-5:2015
EN 60079-7:2015
EN 60079-11:2012
EN 60079-18:2015
EN 60079-28:2015
EN 60079-31:2014
Ex db eb qb [ib op pr] IIC T4 Gb
Ex tb IIIC T120 °C Db
IECEx IBE 11.0007X
IEC 60079-0:2011 Edition: 6
IEC 60079-1:2014-06
Edition: 6
IEC 60079-5:2015 Edition: 4
IEC 60079-7:2015
Edition: 5
IEC 60079-11:2011
Edition: 6
IEC 60079-18:2015
Edition: 4
IEC 60079-28:2015
Edition: 2
IEC 60079-31:2013
Edition: 2
The intrinsically safe circuits and the enclosure are
galvanically connected. The equipotential bonding
must be guaranteed at the installation of the
intrinsically safe circuits.
High charging mechanisms at the operation surface
of the Visual units respectively accessories (for
example pneumatic particle transport) must be
excluded at the application. The degree of
protection (IP code) must be ensured by the
installation of the units in enclosures (IP code).
Technical data subject to change.
08/2019