Keyboard; Explosion Protection; General Data - Bartec POLARIS Remote KVM Analog Series User Manual

15" / 19.1"
Table of Contents

Advertisement

Technical data
4.2

Keyboard

4.2.1

Explosion protection

4.2.2

General data

EN 12/48
POLARIS REMOTE
- for Zone 1/21
POLARIS Remote KVM Analog 15" / 19.1"
Type
Ex protection type ATEX
Certification
Ex protection type IECEx
Certification
Ex protection type
Certification
More test certificates
Construction
Material
Protection class (front)
Dimensions
(width x height)
Wall cut-out
(width x height)
Installation depth
Weight
Other features
Dimensions and wall cut-out for keyboard (mm)
17-71VZ-40..
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T120°C Db
-20 °C ≤ Ta ≤ +60 °C (50°C)
IBExU 05 ATEX 1117 X
Ex ib IIC T4 Gb
Ex ib IIIC T120 °C Db
IECEx IBE 11.0007X
Class I, Zone 1
(A)Ex ib IIC T4; Gb
Class II, Zone 21
(A)Ex ib IIIC T120 °C; Db
CSA 15.70010166
www.bartec.de
Front panel fitting
Polyester foil on aluminium sheet
(conditionally UV-resistant)
IP65
420 mm x 170 mm
391 mm x 140 mm
18 mm
approx. 700 g
Keyboard available in various languages