  • Page 1 POLARIS BASIC 5.7" up to 12.1" Zone 1/Zone 21 User Manual...
  • Page 3 User Manual - TRANSLATION POLARIS BASIC POLARIS Panel PCs 5.7" / 10.4" / 12.1" Type 17-71V1-…. ATEX / IECEx / CSA Zone 1 and Zone 21 Document no. 11-71V1-7D0004 / 236275 Revision 5 / Status: 30 June 2017 Reservation: Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages.
  • Page 4: Table Of Contents

    POLARIS BASIC - for Zone 1/21 Table of Contents POLARIS Panel PCs 5.7" / 10.4" / 12.1" Basic safety instructions ........................1 Notes on this manual ........................ 1 1.1.1 Languages ........................2 1.1.2 Changes in the document ..................... 2 Handling the product ......................... 2 Intended use ..........................
  • Page 5 6.6.6 TTY interface (optional) ....................28 6.6.7 RS232 interface (optional) ..................29 Ex i terminal compartment ...................... 30 6.7.1 Ex i USB interface for BARTEC Ex i memory stick............. 30 6.7.2 Connection of a BARTEC BCS 160 hand scanner (optional) ........31 EMC (Electromagnetic compatibility) ..................
  • Page 6 blank...
  • Page 7: Basic Safety Instructions

    The BARTEC company reserves the right to carry out technical changes at any time. In no event will BARTEC company be responsible or liable for indirect or consequential damages resulting from the use or application of this user manual.
  • Page 8: Languages

    1.1.2 Changes in the document BARTEC reserves the right to change the content of this document without notification. No warranty is assumed for the correctness of the information. In cases of doubt, the German safety instructions apply because it is not possible to rule out errors of translation or printing.
  • Page 9: Unintended Use

    POLARIS BASIC - for Zone 1/21 Basic POLARIS Panel PCs 5.7" / 10.4" / 12.1" safety instructions 1.3.2 Unintended use Any other use is not in accordance with the intended purpose and can cause damage and accidents. The manufacturer will not be liable for any use beyond that of its exclusive intended purpose.
  • Page 10: Servicing

    The device features an explosion protection label, as well as a test certificate. For an explanation of the symbols and information used, see chapter 4 "Technical data". The POLARIS BASIC series complies with Directive 2014/34/EU on equipment and protective systems intended for use in potentially explosive atmospheres (ATEX Directive).
  • Page 11 BARTEC grants a warranty period of one year on the POLARIS series, starting from the BARTEC delivery date. The warranty period for accessories is 1 year from the date of delivery. This warranty covers all parts of the delivery and is limited to the free-of- charge replacement of or repair of the defective parts by BARTEC.
  • Page 12: Product Description

    Illustration 1: POLARIS BASIC - Series With the POLARIS BASIC Series it is possible to connect directly to the potentially explosive area process visualisations without additional intrinsically safe separator cards. The laying of blue lines for intrinsically safe circuits is dropped. A separate wiring of the data line is not necessary.
  • Page 13: Schematic Design

    Illustration 3: Visualisation software BMS-Graf-pro Version 6.xxx Standard assembly of the POLARIS BASIC Series is mounting on the front panel which can be performed quickly and easily. On request we also supply the POLARIS BASIC Series as turn-key system solution in a stainless steel enclosure for wall and floor mounting.
  • Page 14: Explosion Protection And Approvals

    Explosion protection and POLARIS BASIC - for Zone 1/21 approvals POLARIS Panel PCs 5.7" / 10.4" / 12.1" Explosion protection and approvals POLARIS BASIC Type 17-71V1-…. ATEX Ex protection type II 2G Ex eb qb [ib op pr] IIC T4 bzw.
  • Page 15 POLARIS BASIC - for Zone 1/21 Explosion protection and POLARIS Panel PCs 5.7" / 10.4" / 12.1" approvals Further test certificates INMETRO 11/UL-BRHZ-0131X Customs Union Russia (EAC) TC RU C-DE.GB06.B.00334 Korea KTL 14-KB4BO-0258X India CCEs P261984 More test certificates www.bartec.de...
  • Page 16: Technical Data

    POLARIS BASIC- for Zone 1/21 Technical data POLARIS Panel PCs 5.7" / 10.4" / 12.1" Technical data General data Construction Front panel fitting, optional turn-key system solutions in a stainless steel enclosure as floor or wall mounting. Computer capacity Processor 500 MHz 256 MB RAM Compact Flash 512 MB Power supply...
  • Page 17: Characteristics Polaris Panel Pc 5.7

    POLARIS BASIC - for Zone 1/21 Technical data POLARIS Panel PCs 5.7" / 10.4" / 12.1" 4.1.1 Characteristics POLARIS Panel PC 5.7" Display 5.7" graphics-capable TFT colour display 262,144 colours QVGA resolution 320 x 240 pixels Brightness 400 cd/m Visible surface approx. 116 mm x 88 mm...
  • Page 18: Characteristics Polaris Panel Pc 12.1

    POLARIS BASIC- for Zone 1/21 Technical data POLARIS Panel PCs 5.7" / 10.4" / 12.1" 4.1.3 Characteristics POLARIS Panel PC 12.1" Display 12.1" graphics-capable TFT colour display 262,144 colours SVGA resolution, 800 x 600 pixels Brightness 350 cd/m Visible surface approx. 249 x 188 mm Contrast 400:1 Antireflection coating glass pane Backlighting...
  • Page 19: Product Labelling

    License sticker Test sticker Since 01.01.2016, all devices of the POLARIS BASIC series are delivered with an operating system: "Free DOS". "Free DOS" is an MSDOS compatible operating system, which falls under GNU (General Public License) and is thus freely available.
  • Page 20: Transport, Storage, Scope And Assembly

    A written report of any transport damage or missing items must be given to the appointed forwarder and to BARTEC GmbH immediately on receipt of the delivery. Damage caused by incorrect storage and transport shall not fall within the warranty provisions of BARTEC GmbH.
  • Page 21: Assembly

    POLARIS BASIC - for Zone 1/21 Transport, storage, POLARIS Panel PCs 5.7" / 10.4" / 12.1" scope and assembly Assembly Before assembling the device, make sure you have all the components and documents. POLARIS 1 x hex key 3 mm...
  • Page 22: Installation

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" Installation We recommend setting up and testing the entire system before its ultimate installation in the ex-area. If a long connection cable is not available, please use a patch cable to test the basic functions.
  • Page 23: Mechanical Installation

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" The POLARIS must be heated when at temperatures below 0°C. We furthermore – recommend protecting the display from the cold, e.g. with a door on the front of the enclosure.
  • Page 24 POLARIS and tighten to 1.37 Nm. Tighten the clamping screw (3) of the mounting clamps to a torque of 1.02 Nm. Number of retaining claws POLARIS BASIC 5.7" / 10.4" / 12.1" 6 pieces Always tighten the mounting clamps crosswise.
  • Page 25: Installation As A System Solution In The Stainless Steel Enclosure

    (M12) (e.g. dowels or stud bolts). Stainless steel enclosure "Standard" for floor and wall mounting Dimensions (Width x Height x Depth) Type POLARIS BASIC 5.7″ 500 mm x 280 mm x 200 mm POLARIS BASIC 10.4″ 560 mm x 320 mm x 200 mm POLARIS BASIC 12.1″...
  • Page 26: Floor Mounting Stainless Steel Enclosure

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" 6.2.3 Floor mounting stainless steel enclosure Illustration 8: Base – drilling template base plate 6.2.4 Wall mounting Stainless steel enclosure Illustration 9: Wall mounting – dimensions of mounting straps Technical data subject to change.
  • Page 27: Electrical Installation

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" Electrical installation 6.3.1 Installation guidelines Only qualified personnel, i.e. trained electricians will have the required specialised knowledge to be able to do all the electrical work.
  • Page 28: Terminal Compartments

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" Terminal compartments DANGER Sealed locking screw! The device is closed in the factory. The explosion protection is lost if opened, and danger to life exists in...
  • Page 29: Pe Conductor Connection

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" PE conductor connection DANGER Death or danger of injury as a result of no PE conductor connection. There is no explosion protection. Equipotential bonding with a core cross-section of at least 4 mm is to be set up for ...
  • Page 30: Ex E Terminal Compartments

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" Ex e terminal compartments 6.6.1 Cable entries When connecting cables and leads to supplies / communications equipment in increased safety protected areas, Ex certified cable entries must be used which are suitable for each type of cable and lead.
  • Page 31: Ethernet Terminal Assignment

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" 6.6.3 Ethernet terminal assignment Configuration Ethernet 10BaseT Terminal Interface Signal Remarks Ethernet RxD + 10BaseT Receive positive Ethernet RxD - 10BaseT Receive negative Ethernet TxD +...
  • Page 32 RS485 connection mode (semi duplex) Maximum length of the data line 1,000 m. BARTEC delivers all RS485 interfaces as RS422. If the RS422 interface is used as RS485, external bridges must be placed between pin 23/pin 25 and between pin 24/pin 26.
  • Page 33: Profibus-Dp Interface (Optional)

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" 6.6.5 PROFIBUS-DP interface (optional) Configuration PROFIBUS-DP (BARTEC) Terminal Interface Signal Remarks not connected not connected Interface COM 1 Termination B2 Bridge for terminating network (B1-B2)
  • Page 34: Tty Interface (Optional)

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" 6.6.6 TTY interface (optional) Configuration TTY Terminal Interface Signal Remarks Not connected Not connected Interface COM 1 Signal ground for receiver Interface COM 1 Cathode...
  • Page 35: Rs232 Interface (Optional)

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" 6.6.7 RS232 interface (optional) Configuration RS232 Terminal Interface Signal Remarks Not connected Not connected Not connected Not connected Not connected Not connected Not connected Interface COM 1...
  • Page 36: Ex I Terminal Compartment

    The cover for the Ex i terminal compartment need not be used when deploying a protective enclosure with protection class of at least IP20. 6.7.1 Ex i USB interface for BARTEC Ex i memory stick USB socket, 4-pole, Type A ATTENTION The Ex i interface has not been designed for USB devices with their own power supply.
  • Page 37: Connection Of A Bartec Bcs 160

    55.8 µF The BCS 160 hand scanner series can only be used with the original connection cable from BARTEC. Not compatible is the hand scanner BCS 160 with 1D/2D Imager (Type 17-21BA-M31S/I0000000) Connection cable to BCS 160 Barcode hand scanner (pre-assembled)
  • Page 38: Emc (Electromagnetic Compatibility)

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" EMC (Electromagnetic compatibility) This is a class A unit and can cause radio interference in residential areas; if it does, the owner/managing operator may be required to implement suitable measures and pay for loss or damage.
  • Page 39: Back-Up Fuse

    6.8.2 Back-up fuse The POLARIS BASIC Series with DC 24 V is internally protected by a slow 1.6 A fuse. The fuse can trip in the case of voltage drops or undervoltage. We recommend protecting the devices with a fast-acting 1.6 A back-up fuse to prevent the tripping of the internal fuse in the device.
  • Page 40: Examples Of Shielding Connections

    POLARIS BASIC - for Zone 1/21 Installation POLARIS Panel PCs 5.7" / 10.4" / 12.1" 6.8.6 Examples of shielding connections ATTENTION Device can be damaged by differences in potential! Avoid differences in potential.  Double-sided shield connection on the connecting cables...
  • Page 41: Commissioning

    POLARIS BASIC - for Zone 1/21 Commissioning POLARIS Panel PCs 5.7" / 10.4" / 12.1" Commissioning For electrical systems the relevant installation and operating specifications (e.g. Directives 2014/34/EU, BetrSichV and the applicable national ordinances, IEC 60 079-14 and the DIN VDE 0100 series) must be observed.
  • Page 42: Operation

    Series. The licence sticker can be found on the back of the POLARIS (Until 12/31/2015). Since 01.01.2016, all devices of the POLARIS BASIC series are delivered with an operating system: "Free DOS". "Free DOS" is an MSDOS compatible operating system, which falls under GNU (General Public License) and is thus freely available.
  • Page 43 POLARIS BASIC- for Zone 1/21 Operation POLARIS Panel PCs 5.7" / 10.4" / 12.1" Download via PROFIBUS is not possible. Transfering a project with BMS-Graf pro to the POLARIS Select the menu item with the “Enter” button. – Enter the password. –...
  • Page 44: Faults And Troubleshooting

    The backlighting is coming to the end Dark background of its service life. Replace the backlighting Check that the BARTEC Ex i memory The wrong USB stick has been used. stick is being used. No transfer of project Incorrect format...
  • Page 45: Maintenance, Inspection, Repair

    POLARIS BASIC- for Zone 1/21 Maintenance, inspection, POLARIS Panel PCs 5.7" / 10.4" / 12.1" repair Maintenance, inspection, repair Only trained and qualified personnel may commission and do maintenance work on the POLARIS! Trained qualified personnel are people who are familiar with the installation, assembly, commissioning and operation of the POLARIS, have been instructed about the risks and have the appropriate qualifications by virtue of the work they do.
  • Page 46: Instructions For Repairs

    If you wish to send in a defective device for repair, please read the RMA procedure guidance first. Then fill in and sign the RMA (Return Merchandise Authorisation) form and send it to our "Retouren Center". E-Mail: services@bartec.de Fax: +49 7931 597-119 We cannot guarantee any contractually agreed processing times for devices that are sent in without an RMA number.
  • Page 47: Accessories, Spare Parts

    POLARIS BASIC- for Zone 1/21 Accessories, spare parts POLARIS Panel PCs 5.7" / 10.4" / 12.1" Accessories, spare parts Included in the scope of the delivery: Name Order no. Mounting clamps 6 pieces 05-0091-0112 Reinforcement frame POLARIS 5.7" 05-0205-0006 POLARIS 10.4" 05-0205-0008 POLARIS 12.1"...
  • Page 48: Order Numbers

    POLARIS BASIC- for Zone 1/21 Order numbers POLARIS Panel PCs 5.7" / 10.4" / 12.1" Order numbers Panel PC 5.7" Panel PC 10.4" Panel PC 12.1" Technical data subject to change without notice. EN 48/45 06/2017...
  • Page 49: Additional Information

    POLARIS BASIC- for Zone 1/21 Additional information POLARIS Panel PCs 5.7" / 10.4" / 12.1" Additional information Technical data subject to change. EN 43/45 06/2017...
  • Page 50: 16. Declaration Of Conformity

    POLARIS BASIC - for Zone 1/21 Declaration of conformity POLARIS Panel PCs 5.7" / 10.4" / 12.1" 16. Declaration of conformity Technical data subject to change. EN 42/45 06/2017...
  • Page 51 POLARIS BASIC - for Zone 1/21 Declaration of conformity POLARIS Panel PCs 5.7" / 10.4" / 12.1" All certificates see www.bartec.de Technical data subject to change. EN 45/45 06/2017...
  • Page 52 Your partner for safety technology. Challenge us! BARTEC GmbH Max-Eyth-Str. 16 97980 Bad Mergentheim Germany Phone: +49 7931 597-0 info@bartec.de www.bartec.de...