Do not mount in direct proximity to switching or current changing devices.
Only install the POLARIS in conjunction with the reinforcement frame in an IP65
enclosure. Failure to comply with this can lead to water penetrating and damaging
the device.
Outdoor installation
ATTENTION
Damage from condensation or overheating!
Avoid direct sunlight!
Remedy: e.g. shelter with sufficient air circulation.
Remove condensation on the POLARIS immediately.
A POLARIS built into an enclosure must be heated and not removed
from the mains.
Equip the protective housing with breather.
CAUTION
This device is heavy (23-38 kg).
There is a risk of injury if it is lifted or moved incorrectly.
You will need help from others when transporting it.
Only qualified personnel, i.e. trained skilled specialists will have the necessary
specialised know-how to be able to perform all the mechanical work. Familiarity with
and the technically perfect implementation of the safety instructions described in this
manual are preconditions for safe installation and commissioning.
In order to guarantee the IP degree of enclosure protection = IP54 for installation in 2G
enclosures of Ex e type of protection (e.g. control equipment), and = IP6X for installation
in 2D enclosures in areas where combustible dusts exist - with "protection through the
enclosure" type of protection - the reinforcement frame should be used for fastening on
the front side.
A reinforcement frame is inserted between the retaining brackets and the enclosure
material for good transmission of the clamping force. This ensures even transmission of
force.
For POLARIS built into the enclosure door
The open door must be supported and secured during the installation and servicing
phase. Otherwise the wall thickness specified may lead to the door sagging slightly
when open.