Polaris zero client 12,1" w / 15" / 17,3" / 19,1" / 24" atex zone 2 and zone 22 (96 pages)
Summary of Contents for Bartec POLARIS Remote KVM Digital 17-71V2 Series
Page 1
ATEX / IECEx Zone 1 and Zone 21 POLARIS User Manual POLARIS REMOTE POLARIS Remote KVM Digital 15" to 24" Type 17-71V2-..
Page 3
Reservation: Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages. Contents Page English 1 - 48 GmbH Contact: Max-Eyth-Straße 16 Phone: +49 7931 597-0 support-polaris@bartec.de 97980 Bad Mergentheim Fax: +49 7931 597-119 Download: Germany www.bartec.de/automation-download...
POLARIS REMOTE Contents POLARIS Remote KVM Digital Basic Safety Instructions ....................1 Notes on this manual ....................1 1.1.1 Languages ....................... 2 1.1.2 Changes to the document ................2 Handling the Product ....................2 Use in Accordance with the Intended Purpose ............2 1.3.1 Exclusive Purpose ...................
Page 5
5.6.4 Terminal assignment LSA-Plus Terminal (X17-1 to X17-8) ......33 Ex i terminal compartment ..................34 5.7.1 Connection of Ex i keyboard to the POLARIS (optional) ....... 34 5.7.2 Connection of a BARTEC BCS 160 hand scanner (optional) ..... 35 Local Unit ........................36 5.8.1 Technical Data for Local Unit ................
POLARIS REMOTE Basic POLARIS Remote KVM Digital Safety Instructions 1 Basic Safety Instructions 1.1 Notes on this manual Please read carefully before commissioning the devices. The user manual is a constituent part of the product. It must be kept in the direct vicinity of the device and accessible at all times to installation, operating and maintenance personnel.
BARTEC or request them when placing the order. 1.1.2 Changes to the document BARTEC reserves the right to alter the contents of this document without notice. No guarantee is given for the correctness of the information. In case of doubt, the German safety instructions shall apply because it is not possible to rule out errors in translation or in printing.
POLARIS REMOTE Basic POLARIS Remote KVM Digital Safety Instructions 1.4 Owner’s/Managing Operator’s Obligations The owner/managing operator undertakes to restrict permission to work with the POLARIS to people who: are familiar with the basic regulations on safety and accident prevention and have ...
Basic POLARIS REMOTE Safety Instructions POLARIS Remote KVM Digital 1.7 Inspection Under EN/IEC 60079-17 and EN/IEC 60079-19, the owner/managing operator of electrical installations in hazardous areas is obliged to have these installations checked by a qualified electrician to ensure that they are in a proper condition. 1.7.1 Repairs Repairs on explosion-protected operating equipment may be done only by authorised persons working in accordance with the latest developments in technology and using...
Page 11
POLARIS REMOTE Basic POLARIS Remote KVM Digital Safety Instructions As a fundamental rule, our “General Conditions of Sale and Delivery” apply. These are made available to the owner/managing operator at the latest on formation of a contract. Guarantee and liability claims for personal injury and damage to property are excluded if they are due to one or more of the following reasons: use of the POLARIS for a purpose other than that for which it is intended.
Intrinsically safe keyboards in various national languages, and mouse, trackball, joystick and touchpad as front-panel installation are available. A resistive (intrinsically safe) touch screen and the connection of a BARTEC hand-held scanner are optional possibilities. The intrinsically safe input devices are supplied through barriers which are also integrated in the POLARIS Remote.
POLARIS REMOTE Product Description POLARIS Remote KVM Digital 2.2 System Design There is firmware on both the unit remote and local unit which must have the same firmware status for smooth transmission. 2.2.1 Standard – Point to Point Local operation and the remote station are peers in the system Illustration 1: System design with STP cable up to 130 m 2.2.2 Standard - Point-to-Point with Hand-Held Scanner The local operation and the remote station are peers in the system.
POLARIS REMOTE Product Description POLARIS Remote KVM Digital 2.2.3 Special Application - Cascade Connection When several POLARIS Remote devices are cascaded, the POLARIS Remote devices are peers in the system. The use of the touch function must be checked in each individual case.
The degree of protection (IP code) must be ensured by the installation of the units in enclosures (IP code). Directives 94/9/EG 2004/108/EG Product marking 0044 Further test certificates www.bartec-goup.com Subject to technical changes. EN 9/48 Version: 07-2015 / Revision A...
POLARIS REMOTE Technical Data POLARIS Remote KVM Digital 3.1.2 General data Construction Front panel fitting; Optional turn-key system solutions in a stainless steel enclosure as wall, floor or table mounting versions. Connection to the PC with local unit (plug & play) through STP/S copper cable connections 1 x HDMI/DVI in...
POLARIS REMOTE Technical Data POLARIS Remote KVM Digital 3.1.6 Characteristics POLARIS Remote 24" Display 24" graphics-capable TFT display WSXGA resolution, 1920 x 1080 pixels 16.7 million colours Brightness 300 cd/m Visible surface approx. 521 x 299 mm Contrast 3000:1 Backlighting LED technology, Service life approx.
POLARIS REMOTE Technical Data POLARIS Remote KVM Digital 3.2 Keyboard 3.2.1 Explosion Protection Type 17-71VZ-40.. Ex protection type ATEX II 2G Ex ib IIC T4 II 2D Ex ib IIIC T120°C -20 °C ≤ Ta ≤ +60 °C Certification IBExU 05 ATEX 1117 X Standards EN 60079-0:2012 EN 60079-11:2012...
POLARIS REMOTE Technical Data POLARIS Remote KVM Digital Dimensions and wall cut-out for keyboard (mm) All hole diameter: 3.3 mm 3.2.3 Characteristics of enclosure for mouse and keyboard Order no. 05-0041-0277 Material Stainless steel 1.4301; AISI 304 Dimensions 600 mm x 85 mm x 220 mm (width x height x depth) Protection class IP65...
POLARIS REMOTE Technical Data POLARIS Remote KVM Digital 3.3 Finger mouse, Trackball, Touchpad and Joystick 3.3.1 Explosion protection Ex protection type ATEX II 2G Ex ib IIC T4 II 2D Ex ib IIIC T120°C -20 °C ≤ Ta ≤ 60 °C Certification IBExU 05 ATEX 1117 X Standards...
Page 24
POLARIS REMOTE Technical Data POLARIS Remote KVM Digital Finger mouse Type 17-71VZ-1000 Installation depth 15 mm Weight approx. 270 g Touchpad Type 17-71VZ-2000 Installation depth 15 mm Weight approx. 250 g Trackball Type 17-71VZ-3000 Installation depth 43 mm Weight approx. 500 g Joystick without button Type 17-71VZ-8000...
POLARIS REMOTE Technical Data POLARIS Remote KVM Digital 3.4 Product Labelling Type label Warnings on the device Label for Local Unit Type label with label INMETRO Test sticker Subject to technical changes. EN 19/48 Version: 07-2015 / Revision A...
A written report of any transport damage or missing items must be given to the appointed forwarder and to BARTEC GmbH immediately on receipt of the delivery. Damage caused by incorrect storage and transport shall not fall within the warranty provisions of BARTEC GmbH.
POLARIS REMOTE Transport, Storage, Scope POLARIS Remote KVM Digital and Assembly 4.4 Assembly Before assembling the device, make sure you have all the components and documents. Required Tools: POLARIS 1 x hex key 3 mm (mounting clamps) 1 x slotted screwdriver POLARIS 1 x hex key 2.5 mm termination compartments...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5 Installation We recommend setting up and testing the entire system before its ultimate installation in the Ex area. If a long connection cable is not available, please use a patch cable to test the basic functions.
Page 29
POLARIS REMOTE Installation POLARIS Remote KVM Digital POLARIS with CFL backlighting: The POLARIS must be heated when at temperatures below 0 °C. We furthermore recommend protecting the display from the cold, e.g. with a door on the front of the enclosure.
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.2 Mechanical Installation CAUTION This device is heavy (23-38 kg). There is a risk of injury if it is lifted or moved incorrectly. You will need help from others when transporting it. Only qualified personnel, i.e.
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.2.1 Installation in 2G/3D enclosure In order to guarantee the IP degree of enclosure protection = IP54 for installation in 2G enclosures of Ex e type of protection (e.g. control equipment), and = IP6X for installation in 2D enclosures in areas where combustible dusts exist - with “protection through the enclosure”...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.2.2 Installation as a System Solution in the Stainless Steel Enclosure The POLARIS is available as a ready-made system solution in a stainless steel enclosure e.g. the "Exclusive" stainless steel enclosure, for floor, wall or table mounting. Work steps: Prepare supply and data line(s).
Page 33
POLARIS REMOTE Installation POLARIS Remote KVM Digital Wall mounting (Stainless steel enclosure "Exclusive") Illustration 8: Drilling pattern - supporting system for wall mounting Table mounting swivel/tilt (Stainless steel enclosure "Exclusive") CAUTION Movable enclosure parts on the swivel-mounted enclosure. There is a risk of injury by hands being crushed. 3 people are needed for assembly/disassembly.
Page 34
POLARIS REMOTE Installation POLARIS Remote KVM Digital Inclining The POLARIS is fixed in position by means of the two side handle screws. The angle of inclination can be changed once both handle screws have been loosened. Tools: hex key 5 mm Illustration 10: Swivel-mounted adapter Rotating The POLARIS is fixed in position on the supporting system by means of two hexagon...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.3 Electrical Installation 5.3.1 Installation guidelines Only qualified personnel, i.e. trained electricians will have the required specialised knowledge to be able to do all the electrical work. Familiarity with and the technically perfect implementation of the safety instructions described in this manual are preconditions for safe installation and commissioning.
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.4 Terminal compartments DANGER Sealed locking screw! The device is closed in the factory. The explosion protection is lost if opened, and danger to life exists in an explosive atmosphere! Do not open the locking screw! ...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.5 PE conductor connection DANGER Death or danger of injury due to lack of PE conductor connection. An external PE conductor connection is necessary for metal enclosures. PE conductor, see illustration. PE conductor connections must be secured against accidental loosening. ...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.6 Ex e terminal compartments 5.6.1 Cable entries When connecting cables and leads to supplies / communications equipment in increased safety protected areas, it is essential to use Ex certified cable entries which are suitable for each type of cable and lead.
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.6.3 Terminal Assignment for USB Only for external keyboard and mouse. Terminal Interface Signal Comments Ex e USB VCC (+5V) Ex e USB - Data Ex e USB + Data Ex e USB 5.6.4 Terminal assignment LSA-Plus Terminal (X17-1 to X17-8) POLARIS Remote STP-cable...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.7 Ex i terminal compartment Do not connect the keyboard, mouse, trackball, touchpad, joystick or the hand-held scanner while the power supply is active. DANGER Accessories which have not been approved jeopardise the explosion protection. Danger to life exists in an explosive atmosphere! Only use POLARIS accessories! ...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.7.2 Connection of a BARTEC BCS 160 hand scanner (optional) Do not connect the hand scanner when there is an active power supply. Configuration of hand scanner connection (optional) Terminal Interface Signal Remarks...
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.8 Local Unit ATTENTION In the POLARIS Remote KVM Digital System the internal firmware of the local unit is coordinated with the remote unit. The same firmware release must be used. The firmware status is printed on the POLARIS Remote KVM Digital and on the local unit or can be read out during operation (see KVM operating instructions).
POLARIS REMOTE Installation POLARIS Remote KVM Digital 5.9 EMC (Electromagnetic Compatibility) This is a class A unit and can cause radio interference in residential areas; if it does, the owner/managing operator may be required to implement suitable measures and pay for loss or damage. Only shielded conductors may be used as connecting conductors.
The fuse may be triggered in the case of voltage dips or undervoltage. We recommend protecting the POLARIS with an upstream fuse to prevent blowing the fuse inside the device. Only BARTEC can change the internal fuse. Back-up fuse AC: 1.6 A slow-blowing (since June 2015: 2.5 A) DC: 4 A quick-acting.
Page 45
POLARIS REMOTE Installation POLARIS Remote KVM Digital Connection of shielding A low impedance connection to the circuit protective conductor is important to ensure a low current fault path. When sub-D connectors are used, the shielding should always be connected to the metal casing of the sub-D plug. The plug casing of some controllers is not always well connected to earth.
POLARIS REMOTE Commissioning POLARIS Remote KVM Digital 6 Commissioning For electrical systems the relevant installation and operating specifications (e.g. Directives 99/92/EC and 94/9/EC, BetrSichV and the applicable national ordinances, IEC 60 079-14 and the DIN VDE 0100 series) must be observed. The operator of an electrical system in a hazardous environment must keep the operating equipment in an orderly condition, operate it correctly, monitor it and do the required maintenance and repairs.
The touch driver for the respective operating system must be installed on the local server or PC. There is also the option of downloading the touch screen software from http://www.bartec.de/automation-download/. After installation, the touch screen must be calibrated. The transmission is done via USB cable for the keyboard and mouse.
Faults and POLARIS REMOTE Troubleshooting POLARIS Remote KVM Digital 8 Faults and Troubleshooting Fault Possible Cause Remedy Check the “Power/Status” LED No signal on the local unit Check the power supply connection. / LED on the local unit is red (remote station and local unit) i.e.
POLARIS REMOTE Maintenance, Inspection, POLARIS Remote KVM Digital Repair 9 Maintenance, Inspection, Repair Only trained and qualified personnel may commission and do maintenance work on the POLARIS! Trained qualified personnel are people who are familiar with the installation, assembly, commissioning and operation of the POLARIS, have been instructed about the risks and have the appropriate qualifications by virtue of the work they do.
If you wish to send in a defective device for repair, please read the RMA procedure guidance first. Then fill in and sign the RMA (Return Merchandise Authorisation) form and send it to our "Retouren Center". E-mail: services@bartec.de Fax: +49 7931 597-119 We cannot guarantee any contractually agreed processing times for devices that are sent in without an RMA number.
POLARIS REMOTE Disposal, POLARIS Remote KVM Digital Dispach and Packaging 10 Disposal The component of the POLARIS contains metal, plastic parts and electronic components. Our devices are intended as professional electric devices for business use only, referred to as B2B devices under the WEEE-Directive. The WEEE directive sets the framework for waste electric and electronic equipment handling procedures which are to apply throughout the EU.
POLARIS REMOTE Accessories, Spare Parts POLARIS Remote KVM Digital 12 Accessories, Spare Parts Included in the scope of the delivery: Name Order no. Mounting clamps Reinforcement frame POLARIS 15" 05-0205-0009 POLARIS 19.1" 05-0205-0010 POLARIS 24" 05-0205-0012 Local unit RJ45 Network box RJ45 Patch cable Accessories, Spare Parts for POLARIS Remote KVM Digital Name...
POLARIS REMOTE Order Numbers POLARIS Remote KVM Digital 13 Order Numbers POLARIS Remote KVM Digital 15", 19" and 24" POLARIS Remote KVM Digital 15" Sunlight Subject to technical changes. EN 47/48 Version: 07-2015 / Revision A...
POLARIS REMOTE Additional Information POLARIS Remote KVM Digital 14 Additional Information Subject to technical changes. EN 48/48 Version: 07-2015 / Revision A...
Page 55
POLARIS REMOTE Appendix POLARIS Remote KVM Digital Declaration of Conformity All certificates see www.bartec-group.com Subject to technical changes. Version: 07-2015 / Revision A...
Page 56
BARTEC protects p e o p l e a n d the environment b y t h e s a f e t y of components, s y s t e m s a n d p l a n t s .
Need help?
Do you have a question about the POLARIS Remote KVM Digital 17-71V2 Series and is the answer not in the manual?
Questions and answers