Download Print this page

Original Instructions' Manual - Raider Pro RDP-AG42 User Manual

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
EN
Congratulations on the purchase of machinery from the fastest growing brand of electric, gasoline
and pneumatic tools - RAIDER. When properly installed and operating, RAIDER are safe and reliable
machines and work with them will deliver a real pleasure. For your convenience has been built and
excellent service network of 45 service stations across the country.
Before using this machine, please carefully acquainted with these "instructions' manual".
In the interest of your safety and to ensure proper use and read these instructions carefully,
including the recommendations and warnings in them. To avoid unnecessary errors and accidents,
it is important that these instructions will remain available for future reference to all who will use the
machine. If you sell it to a new owner "Instructions' manual" must be submitted along with it to enable
new users to become familiar with relevant safety and operating instructions.
Euromaster Import Export Ltd. is an authorized representative of the manufacturer and owner of
the trademark RAIDER.
Address: Sofia City 1231, Bulgaria "Lomsko shausse" Blvd. 246, tel 02 934 33 33, 934 10 10, www.
raider.bg; www.euromasterbg.com; e-mail: info@euromasterbg.com.
Since 2006 the company introduced the system of quality management ISO 9001:2008 with scope
of certification: Trade, import, export and servicing of hobby and professional electrical, mechanical
and pneumatic tools and general hardware. The certificate was issued by Moody International
Certification Ltd, England.
parameter
Model
Rated power
Current
Frequency
Sound pressure Lp
A
Sound power Lw
Uncertainty K=3
A
Vibrations a
Uncertainty K=1.5
h
No-load speed
Thread of the spindel
Inside diameter of the disc
Max diameter of the disc
Max tickness of the disc
Length of the spindel
Protection class

Original instructions' manual

Dear Customer,
TECHNICAL DATA
Uncertainty K=3
unit
value
RDP-AG42
-
W
750
V
230
Hz
50
dB(А)
96
dB(А)
107
m/s
2.50
2
min
11000
-1
mm
M14
mm
22.23
mm
125
mm
6
mm
20
-
13
II