CHAPTER 4 - DISPLAY CALIBRATION

Set display to be primary or secondary
BATT
Press
Press BATT + FRESH at power up = unit mode (primary/secondary)
set. Display shows "scn". Once in that mode, FRESH = primary
("Pri"), GREY = secondary ("SEc"). Press BATT to save and exit.
Display firmware revision/visual alarm cue
Press
BATT
+ 5 seconds = version/revision. Display shows "rx.y" where x.y is
the firmware revision, for example, "r1 . 2". Release both buttons
to exit.
+ 10 seconds = visual alarm cue. Display shows "cuE". Release
both buttons to edit. Options are either "on" or "oFF". If set
to on, the visual alarm cue will be the 3rd decimal point on the
display. It will remain lit if any tank is in alarm status, even if the
display is off/idle. FRESH toggles on/off, BATT saves new setting
and exits. If the currently displayed tank is in alarm status, the
3rd LED will slowly blink while that tank is being displayed.
Set LED brightness
Press
BATT
+ 5 seconds = brightness menu. Display shows "bri". Release
both buttons to edit. Allowable levels are "b-1" (dimmest) to
"b-5" (brightest). FRESH = dimmer, GREY = brighter. BATT to
save and exit.
Press
BATT
+ 5 seconds = primary/secondary indication. Display shows
either "Pri" or "SEc" depending on whether the display is set to
be a primary or a secondary. Release both buttons to exit.