Flashlight With Intermittence; Stop Input; Photo 1 Input - V2 PD9 Manual

24v digital control unit for single and double-swing gates
Table of Contents

Advertisement

FLASHLIGHT WITH INTERMITTENCE

The control unit PD9 permits the connection of a flashlight
with or without intermittence. If the flashlight is equipped with
an inner intermittence effect, it is necessary to select the
option "Si", but if it has no inner intermittence, it is neces-
sary to select the option "no" in order to make it flash.
TIMER FUNCTION
This function permits to program the time bands of opening
and closing. It is necessary to connect a 24h timer with a
contact normally open in parallel with the START or PEDE-
STRIAN START input. When the timer contact is closed, the
gate gets into opening phase and remains opened until the
contact of the timer opens causing the re-closing of the gate.
IMPORTANT: for a correct functioning it is necessary to
activate the automatic closing (menu Ch.AU.)

STOP INPUT

This menu permits to select the functions associated to the
command of STOP.
no
the input STOP is not available
ProS
the input STOP stops the gate: pressing the command
START the gate continues the motion
invE
the command STOP stops the gate: at the next START
the gate starts moving in the opposite direction.
NOTE: during the pause, the STOP command will stop the
pause time count, the next START command will always close
the gate.

PHOTO 1 INPUT

This input can be activated for the connection of two diffe-
rent safety devices: the photocell or the rib. The rib (contact
normally closed) is an active safety device in opening and
closing (now active during the backlash): its intervention
during the opening phase stops the gate, inverts the motion
for 4 s, without offsetting the doors. On the other hand, the
intervention of the rib in closing phase stops the gate,
inverts the motion with the offset of the doors. The photocell
1 (contact normally closed) is an active security in opening
and closing: the intervention of the photocell during the clo-
sing stops the gate, at its disengagement the gate inverts
the motion.
Differently the intervention of the photocell in opening stops
the gate, at its disengagement the gate starts opening again.
It is necessary to install the photocell 1 properly, in order to
cover the action space of the gate.
no
the opening of PHOTO1 is not available
Cost
the opening of PHOTO 1 is available for the connection
of the rib.
APCh the opening of PHOTO 1 is available for the connection
of the photocell