Start In Opening; Start In Closing; Start In Pause; Pedestrian Start In Opening - V2 PD9 Manual

24v digital control unit for single and double-swing gates
Table of Contents

Advertisement

START IN OPENING

This menu permits to select the functions of start during the
opening phase.
PAUS the command START stop the gate and goes into in
PAUSE.
ChiU
the command START close the gate.
no
the command START is not available.

START IN CLOSING

This menu permits to select the functions of start during the
closing phase.
StoP
the command START stop the gate.
APEr
the command START open the gate

START IN PAUSE

This menu permits to select the functions of the command
start during the standstill.
ChiU
the command START closes the gate.
no
the command START is not available. This function
cannot be selected until the automatic closing has
been activated (menu Ch.AU).

PEDESTRIAN START IN OPENING

This menu permits to select the functions of the command of
START P. during the opening phase.
PAUS the command PEDESTRIAN START stops the gate and
goes in pause.
ChiU
the command PEDESTRIAN START closes the gate.
no
the command PEDESTRIAN START is not available.

THE PHOTOCELL IN PAUSE

This menu permits to determine the functioning of
two photocells during the pause phase.
rPAU the interruption of the photocell's ray
causes the top of the pause time; when
the photocells work again, the pause time
restart from zero.
t.PCh the interruption of the photocell's ray
causes the top of the pause time; when
the photocells work again, the gate stops
for a time to be set between 0 to 2 min.
If the function is t.PCh, the display shows 5.0: set
the wished functions pressing the UP or DOWN keys.
22