DESCRIPTION OF THE CONTROL UNIT • After making connections on the terminal board, use one The digital control unit CITY1 is an innovative V2 product that hose clamp to fix dangerous voltage wires near the terminal guarantees a safe and reliable automation of leaf swing or board and another hose clamp to fix safety low voltage wires sliding gates.
BLINKER provisions in force. CITY1 control unit provides for a 230V 40W (120V – 40W for Connect power supply cables to terminals 30 and 31 of CITY1 model CITY1-120V) blinker equipped with intermittence inside.
SAFETY RIBBONS END OF STROKE The control unit considers two kinds of safety ribbons, CITY1 control unit supports the two following kinds of end of depending on the terminal to which they are connected: stroke: • end of stroke in series of motor winding.
MR1 receiver). The command STOP from remote is operative also if the input STOP of the terminal board is disabled. PLUG IN RECEIVER CITY1 control unit is suitable for plugging in a Personal Pass MR1 ACTIVATION INPUTS receiver having a high-sensitivity super-heterodyne architecture.
CONTROL PANEL USE OF DOWN MENU AND UP KEYS FOR When power is on, the control unit checks that display correctly PROGRAMMING operates by switching on all segments for 1.5 sec. 8.8.8.8. Control unit time and function programming is made within a Firmware version, e.g.
START command must be sent when the door reaches its fully closed position. WARNING: The self-learning procedure must be performed when the encoder (CITY1-ECD) is to be used.
As for both cases, you will have to perform the right exit procedure through item FinE, in order to activate your new configuration. CITY1 control unit provides for a self-learning procedure of working times; therefore, we recommend that you set up a standard configuration first (see previous paragraph), then you carry out the self-learning and finally you change any unsatisfactory items.
Page 10
Leaf 1 closing time Motor 1 will be operated for the setup time in the closing phase; In case there is an obstacle or the end of stroke operates, the control unit can stop the opening phase before the relevant time expires. To avoid that the door does not close completely, we recommend to setup a longer time than t.AP1 opening time.
Page 11
Closing door delay During the closing phase, leaf 1 must start moving after leaf 2, to avoid that both doors may collide. Door 1 closing will be delayed for the setup time. Lock time Before the opening phase begins, the control unit will energize the electric lock in order to release it and enable the gate motion.
Page 12
Motor 1 power This menu allows adjusting the motor 1 power. The displayed value is the percentage of max. motor power. WARNING: In case an hydraulic motor is used, set value 100. Motor 2 power This menu allows adjusting the motor 2 power. The displayed value is the percentage of max.
Page 13
Fast closing time after slowing down If a slowing time other than 0 is set up, it could be likely that the gate speed is not enough for the lock to fasten during the closing phase. In case this function is enabled, once the slowing down phase is finished, the control unit will give a normal speed command (that is to say, with no slowing down) for the set up time, and then it will open the gate for a second fraction, to avoid leaving the motor under stress.
Page 14
Pedestrian Start during the partial opening phase This menu allows fixing the control unit conduct in case it receives a Pedestrian Start command during the partial opening phase. PAUS The gate stops and goes to pause. ChiU the gate immediately starts closing. the gate goes on with the opening phase (command is ignored).
Page 15
Start input function This menu allows selecting input operation modes (see paragraph “Activation inputs”): StAn Start and Pedestrian Start input standard operation, according to menu setups. Start inputs from terminal board are disabled. Radio inputs operate in StAn mode. AP.CH Start impulse always controls the opening phase, Pedestrian Start always controls the closing phase.
Page 16
WARNING: This function is active in case the ends of stroke have been fitted and enabled and if the START IN OPENING has been disabled. WARNING: any improper use of this function may jeopardize the gate safe use. V2 recommends what follows: • Make use of this function only in case the door passage before the photocells is actually unavoidable.
Page 17
No jumper with the common is required. Input enabled. End of Stroke Inputs CITY1 control unit allows connecting four mechanical ends of stroke (normally closed contacts) which are activated by the door motion and showing to the control unit that each door reached its position of complete opening or closing.
Page 18
Such menu allows setting the max. gate quiescent time from 1 to 8 hours. By setting on 0, this function will be disabled. In case the gate stays quiescent (closed) for a time longer than the set time, CITY1 will close the gate for 10 seconds, so restoring an effective closing. Anti-skid...
Page 19
Automatic Learning of the Operation Time This menu will activate a procedure enabling the control unit to automatically find the best duration of the operation time. (See paragraph "Quick Configuration"). When you select Go, configuration menu closes and the learning cycle starts.
READING OF CYCLE COUNTER CITY1 control unit counts the completed opening cycles of the gate and, if requested, it shows that service is required after a fixed number of cycles. There are two counters available: • A totalizing counter for completed opening cycles that cannot be zeroed (option “tot”...
MEMO DISPLAY DATA DESCRIPTION SCor AntE DATA dEF. It does not load the V2 standard data SCor Predefined programming for a typical sliding gate. AntE Predefined programming for a typical two-door gate t.AP1 0.0" ÷ 2.0' Gate 1 opening time 22.5"...
Page 22
Border 2 input (mobile border) FC.En no/Si End of stroke inputs (CITY1 only) FC.En Limit switch / Encoder input (only CITY1-ECD) - Inputs disabled (the controller ignores them) EnCo - Inputs enabled as encoders - Inputs enabled as limit switches...
CABLES TABLE For the wiring to the control unit refer to the following table: SUITABLE CABLE CONNECTION SUITABLE CABLE GLAND [N° WIRES PER SECTION] NETWORK 3 x 1.5 mm PG9: For cables with external Ø from 5 to 8 mm ACTUATOR 4 x 1 mm PG9: For cables with external Ø...
MAINS led does not switch on It means that there is no voltage on CITY1 control unit card. 1. Before acting on the control unit, disconnect through the It means that the limit switches in closing phase have not been disconnecting switch on the power line and remove the released.