Photo 2 Input; Counter Viewing; End Of Programming - V2 PD9 Manual

24v digital control unit for single and double-swing gates
Table of Contents

Advertisement

PHOTO 2 INPUT

The photocell 2 is active in closing: if it is dimmed during the
closing it stops the gate and inverts the motion. The option CFCh
activates the photocell even when the gate is still: closed gate
means that no impulse has been given, either it is in pause or it has
received a STOP command. In this case through all the time of the
darkening of the photocell the control unit does not receive any com-
mand of activation at any opening / closing cycle.
CFCh the input PHOTO 2 is available: the photocell is active in
closing and also when the gate is still
no
the input PHOTO 2 is not available
Ch
the input PHOTO 2 is available: the photocell is active
only during the closing

COUNTER VIEWING

Such a menu allows viewing the number of opera-
tion cycles which such automatism carries out and
it also enables the final user to set up a limit
value in order to show him when the actuators
service is required.
tot.
SErv
Such a function is disabled by default, by pressing
UP the display will view -01.0, which shows a
1000-cycle countdown after which PD9 will show
the final user that a service is required. Such a
number has been rounded off to hundreds and it
can be set up on 1000-step; set up the desired
value, and then press MENU to confirm.
The request for a service will be signalled by means of double blinks
during the whole operation cycle.
WARNING: only a qualified staff shall carry out all service operations.
Once the service has been carried out, the relevant service menu
SErv shall be set up again.
PD9 will continue signalling the request for a service until such para-
meter is not set up.

END OF PROGRAMMING

This menu allows to finish the programming (both default and
personalized) saving the modified data into memory.
no
further corrections to carry out: do not quit the
programming
Si
end of programming
THE INSERTED DATA HAVE BEEN MEMORIZED: THE CONTROL
UNIT IS READY TO BE USED.
25
Total number of completed cycles (the
display views in thousands, press DOWN
to view units).
number of cycles before the next request
for service.

Advertisement

Table of Contents
loading

Table of Contents