24V DIGITAL CONTROL UNIT FOR SINGLE AND DOUBLE-SWING GATES
GB
GATESTORE Ltd
682 Anlaby High Rd
Kingston Upon Hull. HU3 6UZ
tel. 0845 226 3123
fax. 01482 505001
info@gatestore.co.uk
www.vidue.co.uk
PD9
WITH QUALITY SYSTEM
IL n. 155
EDIZ. 05/05/03
COMPANY
CERTIFIED BY QMSI
UNI EN ISO9001

Advertisement

Table of Contents
loading

Summary of Contents for V2 PD9

  • Page 1 GATESTORE Ltd 682 Anlaby High Rd COMPANY Kingston Upon Hull. HU3 6UZ WITH QUALITY SYSTEM tel. 0845 226 3123 CERTIFIED BY QMSI fax. 01482 505001 UNI EN ISO9001 info@gatestore.co.uk www.vidue.co.uk IL n. 155 EDIZ. 05/05/03 24V DIGITAL CONTROL UNIT FOR SINGLE AND DOUBLE-SWING GATES...
  • Page 2: Table Of Contents

    PD9 FUNCTION TABLE ........
  • Page 3: Important Remarks

    3 mm in each pole (EN 60335-1). of one- and two-shutter gates. The design of PD9 has been designed to realize a • After making connections on the terminal board, product that meets all kind of requirements, with a...
  • Page 4: Terminal Connections

    Neutral 230VAC Phase 230VAC MR1 module receiver is provided with 4 channels and each of them is suitable for a command of PD9 control WARNING: we suggest to use the external aerial unit: (model: ANS433) in order to guarantee the maximal range.
  • Page 5: Control Panel

    5 seconds: the set-up. The PD9 unit can be set up in two different program modes: DEFAULT PROGRAM MODE or CUSTOM • for more than 10 minutes the adjustment pitch is PROGRAM MODE.
  • Page 6: Motor Control Function

    • Press UP key to flow the chart from the bottom to ACCUMULATOR INSTALLATION the top. If the antiblackout function is required, a no-maintenan- ce lead accumulator needs to be connected by means • Press MENU key to flow the chart horizontally; for of special coupling terminals, by strictly complying with example, if the t.ChP function is displayed, by the silk screen printing polarities of the control card.
  • Page 7: Standard Programming (Default)

    This type of programming allows loading the V2 ELETTRONICA default program in the memory: the standard data that will be inserted automatically are shown in the table below (in the column DEFAULT DATA). Set the wished function pressing the up or DOWN keys and press MENU key to confirm.
  • Page 8: Gate Delay During Closing

    GATE DELAY DURING CLOSING In order to avoid the colliding of gate's during the closing the time of delay should de introduced r.Ch, which is adjustable from 0 to 2 minutes. In such a case the closing time of gate1 is delayed in comparison to the gate2. LOCK TIME Before the opening phase starts, the gearcase has to energi- ze the electrical lock in order to release it and enable the...
  • Page 9: Start In Opening

    START IN OPENING This menu permits to select the functions of start during the opening phase. PAUS the command START stop the gate and goes into in PAUSE. ChiU the command START close the gate. the command START is not available. START IN CLOSING This menu permits to select the functions of start during the closing phase.
  • Page 10: Automatic Closing

    St.PA) COURTESY LIGHTS Thanks to the connection "courtesy light" the PD9 control unit enables the connection of the courtesy lights (I.E. garden lights), which can work automatically (lights on for the whole cycle) or timed (lights on for a time adjustable from 0 to 999 seconds).
  • Page 11: Flashlight With Intermittence

    FLASHLIGHT WITH INTERMITTENCE The control unit PD9 permits the connection of a flashlight with or without intermittence. If the flashlight is equipped with an inner intermittence effect, it is necessary to select the option "Si", but if it has no inner intermittence, it is neces- sary to select the option "no"...
  • Page 12: Photo 2 Input

    WARNING: only a qualified staff shall carry out all service operations. Once the service has been carried out, the relevant service menu SErv shall be set up again. PD9 will continue signalling the request for a service until such para- meter is not set up. END OF PROGRAMMING This menu allows to finish the programming (both default and personalized) saving the modified data into memory.
  • Page 13: Pd9 Function Table

    PD9 FUNCTION TABLE DISPLAY DATA DESCRIPTION DEFAULT MEMO DATA DATA dEF. no/Si Load V2 ELETTRONICA standard data t.AP1 0.5" ÷ 2.0' Gate 1 opening time 22.5" t.AP2 0.5" ÷ 2.0' Gate 2 opening time 22.5" t.APP 0" ÷ t.AP1 Opening time of pedestrian gate 6.0"...
  • Page 14 PD9 FUNCTION TABLE DEFAULT MEMO DISPLAY DATA DESCRIPTION DATA DATA Ch.AU Automatic closing - The automatic closing is not active (it corresponds to 0) 0.5" ÷ 20' - The gate closes after the setup time) t.LUC=1' LUCi Courtesy Light t.LUC - Lights start time adjustable from 0 to 20 min.