Analog control unit for roller shutters (116 pages)
Summary of Contents for V2 City7
Page 1
V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39.0172.812411 - fax +39.0172.84050 www.remotecontrolgates.co.uk IL n. 252 EDIZ. 22/06/2011 City7 CENTRALE DI COMANDO ANALOGICA PER CANCELLI A BATTENTE ANALOGUE CONTROL UNIT FOR SWING GATES ARMOIRE DE COMMANDE ANALOGIQUE POUR PORTAILS BATTANTS CUADRO DE MANIOBRA ANALÓGICO...
INDEX IMPORTANT REMARKS ......................14 DECLARATION OF CONFORMITY ..................14 DESCRIPTION OF THE CONTROL UNIT..................15 TECHNICAL SPECIFICATIONS....................15 INSTALLATION........................16 POWER SUPPLY........................16 MOTORS..........................16 BLINKER ..........................16 COURTESY LIGHT ........................16 PHOTOCELLS ........................17 SAFETY EDGES ........................17 START INPUT........................18 PEDESTRIAN START ......................18 STOP............................18 PLUG-IN RECEIVER ......................19 EXTERNAL ANTENNA ......................19 ELECTRICAL CONNECTION TABLE ..................20 ADJUSTMENT OF THE POWER AND OPERATIONAL TIMES............21 CONTROL UNIT INDICATORS (LEDS) ..................21...
14:00 to 18:00. • Installation requires mechanical and electrical skills, therefore it shall be carried out by V2 has the right to modify the product qualified personnel only, who can issue the without previous notice; it also declines any...
DESCRIPTION OF THE CONTROL UNIT • Adjustment of motor power and operation time by means of a trimmer. The CITY7 control unit is an innovative V2 product • Quick plug-in connector for inserting a Mr1 guaranteeing safety and reliability for swing gate series receiver.
INSTALLATION BLINKER The control unit provides for the use of a 230V - Installation of the control unit, the safety devices and 40W or accessories must be performed with the power 120V - 40W blinker with built-in intermittence. supply disconnected. Connect the cables to terminals K9 and K10.
PHOTOCELLS Edges can be used with two settings: 1. Edge always active: The control unit has a 24VAC power supply for Intervention of the edge during opening or photocells with switch normally closed, and can closing causes inversion of the direction of perform an operational test before to starting the movement in order to free the body that caused gate opening procedure.
START INPUT Connect the pedestrian start input control device cables between terminals L4 and L8 on the control The START input is preset for connecting devices unit. with the switch normally open. Function depends on the mode of operation set by means of dip-switch 4.
Pay the utmost attention to the direction of insertion of plug-in modules. The MR1 receiver module has 4 channels, each with an associated command on the City7 control unit: • CHANNEL 1 START • CHANNEL 2 PEDESTRIAN START •...
ELECTRICAL CONNECTION TABLE K1 - K2 Courtesy light timer activation switch Antenna Motor 1 open Antenna shield Motor 1 common Opening command for a standard connection device with switch Motor 1 close normally open. Motor 2 open Pedestrian opening command for a Motor 2 common standard connection device with Motor 2 closed...
ADJUSTMENT OF THE POWER AND CABLE GLAND ASSEMBLY OPERATIONAL TIMES The casing can accept 4 cable glands in the special easy-break housings. The power and operating times may be adjusted by The type of cable gland is indicated in the figure. means of 4 trimmers located on the control unit: PLEASE NOTE: POWER:...
PROGRAMMING THE OPERATIONAL LOGIC It is possible for the control unit to use several different operational logic states, by simply moving the dip- switches located on the card. The functions associated with each individual dip-switch are listed below. DIP FUNCTION SETTING DESCRIPTION ON Disabled...
Page 13
DIP FUNCTION SETTING DESCRIPTION Intervention of the photocell during opening or closing ON Always active causes the gate to stop. When the photocell restores, the gate re-opens completely. Photocell Intervention of the photocell during opening is ignored. NOT active Intervention of the photocell during closing causes the gate during opening to re-open completely.