Install Optional Modules, If Any - ABB ACS560 Quick Installation And Start-Up Manual

Standard control program
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

tightening torques: 0.5...0.6 N·m (0.4 lbf·ft)
Notes:
1)
Current [0(4)...20 mA, R
selected with parameter 12.15 AI1 unit selection.
2)
Current [0(4)...20 mA, R
selected with parameter 12.25AI2 unit selection.
3)
Total load capacity of the auxiliary voltage output+24V (X2:10) = 6.0 W (250 mA / 24 V)
- User can use this source for either of theI/O connections (DI1... DI2- RO1 or DI3...DI6 -
RO2~RO3).
4)
The constant speed are set based on the combination of sources as follows:
Source defined by parameter
28.22
0
1
0
5)
The speed reference ramp is set based on the combination of sources as follows:
DI5
parameter 28.71
0
1
6)
Connected with jumpers at the factory.
7)
Applicable for R0~R2 frames only.
8)
Use shielded twisted-pair cables for digital signals.
9)
Ground the outer shield of the cable 360° under the grounding clamp on the grounding
shelf for the control cables.
10)
Input signal
11)
Output signal

Install optional modules, if any

The ACS560-01 drive supports the below option modules:
CMOD-02 power extension module (for R3...R5 frames)
BAPO-01 power extension module (for R0...R2 frames)
BIO-01 I/O extension module (for R0...R2 frames)
Fieldbus module (in frames R0...R2 frames, fieldbus module can be used with BIO-01
also)
For information on supported fieldbus modules, see ACS560 product catalog.
EN - Quick installation and start-up guide 25
< 500 ohm] or voltage [ 0(2)...10 V, R
in
= 100 ohm] or voltage[ 0(2)...10 V, R
in
Source defined by parameter
28.23
0
0
1
Ramp set
Acc/Dec time 1
Acc/Dec time 2
> 200 kohm] input as
in
> 200 kohm] input as
in
Constant speed active
Set speed through AI1
Constant frequency 1
Constant frequency 2
Parameters
Scalar control (default)
28.72 time 1
28.73 Freq deceleration time 1
28.74 time 2
28.75 time 2