Page 3
MAXPRO200 Extreme Bevel Cut Charts 811270 REVISION 0 ENGLISH Original instructions November 2020 Hypertherm, Inc. Hanover, NH 03755 USA www.hypertherm.com...
Page 4
Mathura Road, New Delhi 110044, India HTJapan.info@hypertherm.com (Main Office Email) 91-11-40521201/ 2/ 3 Tel TechSupportAPAC@hypertherm.com (Technical Service Email) 91-11 40521204 Fax HTIndia.info@hypertherm.com (Main Office Email) TechSupportAPAC@hypertherm.com (Technical Service Email) For training and education resources, go to the Hypertherm Cutting Institute (HCI) online at www.hypertherm.com/hci.
Page 5
σε όλες τις γλώσσες που διατίθενται για κάθε εγχειρίδιο από την ψηφιακή βιβλιοθήκη εγγράφων (Documents library) στη διαδικτυακή τοποθεσία www.hypertherm.com. DE (DEUTSCH/GERMAN) WARNUNG! Bevor Sie ein Hypertherm-Gerät in Betrieb nehmen, lesen Sie HU (MAGYAR/HUNGARIAN) bitte die Sicherheitsanweisungen in Ihrer Bedienungsanleitung, das Handbuch für Sicherheit und Übereinstimmung (80669C), das Handbuch für Sicherheit VIGYÁZAT! Mielőtt bármilyen Hypertherm berendezést üzemeltetne,...
Page 6
языках, на которые переведено то или иное руководство, можно также KO (한국어 /KOREAN) загрузить в разделе «Библиотека документов» на веб-сайте 경고! Hypertherm 장비를 사용하기 전에 제품 설명서와 안전 및 규정 준수 www.hypertherm.com. 설명서(80669C), 워터젯 안전 및 규정 준수 설명서(80943C) 그리고 무선...
Page 11
Introduction Methods of reducing emissions Mains supply Hypertherm’s CE-marked equipment is built in compliance with standard EN60974-10. The equipment should be installed and used in Cutting equipment must be connected to the mains supply according to accordance with the information below to achieve electromagnetic the manufacturer’s recommendations.
Page 12
Electromagnetic Compatibility (EMC) Earthing of the workpiece Where the workpiece is not bonded to earth for electrical safety, nor connected to earth because of its size and position, for example, ship’s hull or building steel work, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances.
Page 13
Hypertherm not in strict conformity herein and as follows: if Hypertherm is notified of a defect (i) with respect with Hypertherm’s specifications and in cases of designs, processes,...
Page 14
At all times you will have and maintain insurance in such quantities and types, and with coverage sufficient and appropriate to defend and to hold Hypertherm harmless in the event of any cause of action arising from the use of the products.
Refer to Extreme bevel cut charts on page 19. The standard MAXPRO200 water tube is not compatible with extreme bevel consumables. You must exchange it with the longer water tube (420823) prior to using extreme bevel consumables. MAXPRO200 Instruction Manual...
For example, bevel cutting a 12 mm (.50 inch) workpiece at a 60-degree angle is like cutting a 25 mm (1 inch) workpiece at a 90-degree angle. Refer to Effective thickness. Hypertherm recommends using the default torch-clearance settings to start cutting. Adjust clearance settings only when necessary. Effective thickness Effective thickness...
Page 18
Effective thickness = Workpiece thickness / sin(a) Hypertherm recommends that you use the thickness settings in the cut chart that are most similar to the effective thickness that you want to cut. After cutting starts, adjust thickness settings only as necessary.
Need help?
Do you have a question about the MAXPRO200 and is the answer not in the manual?
Questions and answers