Hard Disk Controller Test; Configuring Raid1 - Inspur i24 Server Acceptance Manual

Table of Contents

Advertisement

Hard Disk Controller Test

4.1

4.1.1 Configuring RAID1

Table 4- 1 Configuring RAID1 Arrays on LSI SAS 3008
Item
Objective
Prerequisites
Procedure
4
Hard Disk Controller Test
Content
To verify that you can configure RAID arrays on the LSI SAS
3008
The server is powered on, and the hard disks are detected
(Prior to software integration and customer authorized).
1.
Power on the server and press Ctrl+C at POST. The screen
for configuring the LSI SAS 3008 controller card is
displayed(This is in legacy mode; UEFI mode needs to be
configured in the BIOS, see the product user manual for
details).
2.
Select LSI SAS 3008, and press Enter.
3.
Select RAID Properties and press Enter.
4.
Select Create RAID1 Volume and press Enter. Press →
to select RAID Disk, and press the Space key to select
two hard disks for configuring RAID1 properties. RAID
Disk for the two hard disks is displayed as Yes. Press C to
configure RAID1 properties. On the displayed screen,
select Save changes then exit this menu and press Enter to
save the settings.
Inspur proprietary and confidential information