Advertisement

Inspur Server i24&NS5162M5
Server Acceptance Manual
1.2
Version
Realease date 2020-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i24 and is the answer not in the manual?

Questions and answers

Summary of Contents for Inspur i24

  • Page 1 Inspur Server i24&NS5162M5 Server Acceptance Manual Version Realease date 2020-01...
  • Page 2 Unless otherwise agreed in the contract, Inspur Group makes no express or implied statement or warranty on the contents of this document. The content of this document may be updated from time to time due to product version upgrades or other reasons.
  • Page 3 Version Update Date Version Prepared / Revised Reviewer Approver Description 2020-01-10 Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 4: Table Of Contents

    Hard Disk Controller Test......................28 Hard Disk Controller Test....................28 4.1.1 Configuring RAID1.................... 28 4.1.2 Configuring RAID5.................... 29 Network Port PXE........................31 5.1.1 Network Port PXE....................31 Customer Acceptance Sign-off Sheet..................33 Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 5: Contents

    The packaging is in good condition and has no water stain. The anti-shock or anti-fall label is green. All components listed in the packing list are intact. Description None Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 6: Chassis

    Content Objective To verify the installation and power-on status of the power supply units (PSUs). Prerequisites The structure of the mainboard and hard disk backplane is intact. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 7 Insert the first PSU into the slot. Connect power cables to the PSU and check that the power status indicator is steady green. Remove the power cable from the second PSU, Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 8: Hardware Detection

    PSU and the server are operating properly. Expected result The server is operating properly during the test. Description None 1.1.4 Hardware Detection Table 1- 6 Hardware Detection Item Content Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 9: Hard Disk Controllers

    No abnormal noise is heard during the startup. Description None 1.1.5 Hard Disk Controllers Table 1- 7 Hard Disk Controllers Item Content To verify that the RAID controller card operates properly.(LSI Objective Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 10 To verify that the RAID controller card operates properly.(LSI Objective SAS 3108) Prerequisites The structure of the mainboard and hard disk backplane is proper, and hard disks are detected after the server is powered Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 11: Alarm, Firmware Version, And Hardware Status Detection

    Procedure Check the front panel indicator for any abnormalities. (Please refer to the maintenance manual for details) Check the power module and network port indicators for Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 12 Details of BMC management function acceptance, please see "2.1 BMC management function acceptance" below. Expected result 1. The BMC Network Configuration can be entered normally in the BIOS. Description None Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 13: Cmc Test

    Enter the default user name and password again, and click Log In. Wait 5 minutes without performing any operation, and click a menu in the navigation tree. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 14 Enter the user name root and the default password, and click Log In. Choose Power on the menu bar, and choose Power Control in the navigation tree. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 15 Table 2- 3 Web Interface—IP Address Configuration on the WebUI Item Content Objective To verify that you can configure an IP address for the server on the WebUI. Prerequisites AC power is supplied to the server. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 16 WebUI. 3. The new IP address takes effect and can be used to log in. Description Acceptance options. Table 2- 4 Web Interface—Firmware Upgrade on the WebUI Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 17 Table 2- 5 Web Interface—CMC System Logs on the WebUI Item Content Objective To verify CMC system logs on the WebUI. Prerequisites AC power is supplied to the server. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 18 Description Acceptance options. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 19: Bmc Test

    Enter the default user name and password again, and click Log In. Wait 5 minutes without performing any operation, and click a menu in the navigation tree. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 20 Log In. 3. Choose Power on the menu bar, and choose Power Control in the navigation tree. 4. On the Virtual Power Buttons page, click Power On and Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 21 Internet Explorer 8.0/9.0/10.0, Firefox 9.0 has been installed on the terminal. The terminal is connected to the BMC network port on the target server over the network. Procedure address box, enter http://xxx.xxx.xxx.xxx Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 22 The terminal is connected to the BMC network port on the target server over the network. Procedure address box, enter http://xxx.xxx.xxx.xxx (xxx.xxx.xxx.xxx is the static BMC ip address that has been set) Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 23 MAC address of the BMC are displayed. Select Automatically obtain IP address and check that all parameters below are unavailable. Select Manually set IP address, enter an IP address, subnet Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 24 2. Enter the user name root and the default password, and click Log In. 3. Choose System > Firmware Upgrade, the Firmware Upgrade page is displayed. 4. Select the BMC software upgrade package and click Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 25 Enter the user name root and the default password, and click Log In. Choose Configuration > Boot Device. Select DVD-ROM and click Save. Restart the server and check whether the setting takes Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 26 1. In the address box, enter http://xxx.xxx.xxx.xxx (xxx.xxx.xxx.xxx is the static BMC ip address that has been set) 2. Enter the user name root and the default password, and Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 27 2. Enter the user name root and the default password, and click Log In. 3. Choose Configuration > Local Users, and view user management information in the right pane. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 28 Expected result 1. Use the initial admin user to manage BMC users, including adding users, deleting users, and changing passwords. Description Acceptance options. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 29: Hard Disk Controller Test

    Disk for the two hard disks is displayed as Yes. Press C to configure RAID1 properties. On the displayed screen, select Save changes then exit this menu and press Enter to save the settings. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 30: Configuring Raid5

    RAID group. Press "↓" to move the cursor to the "Basic Settings" area. Move the cursor to the "Size" area and set the RAID capacity as required. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 31 14. Select "OK" and press "Enter". 15. Exit the CU configuration interface and prompt to restart the system. Restart the server. Expected result RAID5 arrays properties are configured successfully. Description None Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 32: Network Port Pxe

    Before acceptance, the system should be properly installed, and the software and hardware debugging should pass, and the system can run normally. The acceptance project should be confirmed by relevant personnel of both Inspur and the user. During the acceptance and preliminary inspection tests, the personnel of both parties shall perform strict tests against relevant standards.
  • Page 33  Statement: During the actual acceptance test, the acceptance is subject to the contract requirements and the agreement between the two parties. This manual is for reference only. Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 34: Customer Acceptance Sign-Off Sheet

    Customer Representative: Date:______________________ Date:______________________ Test Category Test Item Test Sub-item Result Interface Login □Pass □Fail □N/A CMC Test Web Interface Power-On and □Pass □Fail □N/A Power-Off on the Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 35 Configuration on the WebUI Firmware Upgrade on □Pass □Fail □N/A the WebUI System Logs on the □Pass □Fail □N/A WebUI Remarks: Inspur Representative: Customer Representative: Date:______________________ Date:______________________ Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 36 □Fail □N/A WebUI System Logs on the □Pass □Fail □N/A WebUI User Management □Pass □Fail □N/A Function on the WebUI Remarks: Inspur Representative: Customer Representative: Date:______________________ Date:______________________ Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.
  • Page 37 Conclusion: Totally 22 items are covered in this acceptance test, in which ______ passed, ______ failed, and ______ were not applicable. Inspur Representative: Customer Representative: Date:______________________ Date:______________________ Inspur proprietary and confidential information Copyright © Inspur Electronic Information Industry Co., Ltd.