Operating Mode; Coordinator Mode - Ebyte E70-DTU User Manual

Hide thumbs Also See for E70-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
Node A address 00 01
Node B address 00 02
5.3. Long address transmission
Coordinator short address transmission format: short address + valid data
00 00 00 00 00 00 00 00 00 or FF FF FF
FF FF FF FF FF are broadcast address;
Coordinator
Node A address:
0A 01 AA 45 65 13 12 44
Node B address:
0D 55 18 42 1A 27 29 64
Node C address:
A4 78 02 46 B5 1C 5A 02

6. Operating Mode

M1
Coordinator M ode
0
Normal M ode
0
Dormant M ode
1
Sleep M ode
1

6.1. Coordinator mode

If the user configures the operating mode 4,(M0=0,M1=0)or the user configures the operating mode as 0, the modem
works in the coordinator mode. In the coordinator mode, the coordinator can set up the network, coordinator is the central
node of the network, there must be a coordinator in the network.
The coordinator configurable data input mode is:
Broadcast transmission. When configured to broadcast, all non -dormant devices on the entire network will receive
data. The ACK pin indicates transmission successfully all the time.
Short address transmission, when configured to short address transmission, the user must specify the short address
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
9
HEX
HEX
Format
HEX
HEX
HEX
HEX
M0
Description
0
Set up a network to manage network node
information
1
Send and receive data at any time
0
Low-power reception, sending data at any time
1
Cannot send and receive data, system sleeps
AA BB CC
AA BB CC
Sending:0A 01 AA 45 65 13 12 44 AA BB CC
Receiving:AA BB CC
Null
Null
Transfer data according to input and output
modes
High real-time performance
Receive delay, send need to wake up the
serial port
The fixed baud rate is 115200 8N1
E70 -DTU (433NW30) user manual
Values
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

433nw30

Table of Contents