Ebyte E95-DTU User Manual

Ebyte E95-DTU User Manual

Hide thumbs Also See for E95-DTU:

Advertisement

Quick Links

E95-DTU(433C30-485)

Advertisement

Table of Contents
loading

Summary of Contents for Ebyte E95-DTU

  • Page 1 E95-DTU(433C30-485)
  • Page 2: Table Of Contents

    6. Schematic diagram of connection in test and practical application ..............12 7. Application ............................... 12 8. Notes .................................13 9. Important Statement ............................14 10. Revise history ..............................14 11. About us ................................15 Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 3 E95-DTU(433C30-485) User Manual Disclaimer EBYTE reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited.
  • Page 4: Introduction

    1. Introduction 1.1. Brief Introduction E95-DTU (433C30-485) has a variety of transmission methods, works in the (425 ~ 450.5Mhz) frequency band (default 433Mhz), the radio provides a transparent RS485 interface, uses a plastic shell, rail-type installation structure, supports 8 ~ 28V ( DC ) voltage input. It has the advantage of strong anti-interference ability.
  • Page 5: Quick Start

     equipment is more reliable; 1.3. Quick Start ① Need to prepare 2 E95-DTU (433C30-485) First install the antenna for the digital radio, and then install the power supply, and the user uses the ② power adapter to supply power;...
  • Page 6: Description Of Each Department

    Note: The radio has the function of power-down save mode (the factory default setting is transparent transmission mode), the user needs to switch the corresponding mode according to the M1 and M0 indicators (effective immediately). Description of each department 1.4. Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 7: Installation Dimensions

    Lights up when the power is turned on Send indicator Blinks when sending data Receive indicator Blinks when receiving data Mode indicator Working mode indicator Mode indicator Working mode indicator 1.5. Installation Dimensions Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 8: Interface Definition

    E95-DTU(433C30-485) User Manual 2. Interface definitio 2.1. Power interface description E95-DTU (433C30-485) can be powered by 8 ~ 28V ( DC ) power supply, and the wiring port is connected by wiring terminal ( 2 Pin ). 2.2. Communication interface description E95-DTU (433C30-485) can be connected to the device through RS485 using the terminal block .
  • Page 9: Technical Indicators

    Frequency range frequency spacing Model Number of channels E95-DTU(433C30-485) 433M 425 ~450.5M 100K 256, half duplex Note: In the same area, multiple groups of digital radio stations are used for one-to-one communication at ★ Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 10: Transmit Power Level

    3.7. Length of delivery and subcontracting Model Size Subcontracting Unlimited single input Continuous transmission, data is not divided into packets, E95-DTU(433C30-485) (baud rate ≤ 57600 ) unlimited data packet length Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 11: Working Mode

    E95-DTU(433C30-485) User Manual 4. Working mode E95-DTU has four working modes. If normal communication is required, you need to configure the radio to transparent transmission mode (mode 0) by pressing the button. The default setting of the radio is transparent transmission mode (mode 0).
  • Page 12: Schematic Diagram Of Connection In Test And Practical Application

    6. Schematic diagram of connection in test and practical application 7. Application Ebyte digital radio is suitable for all kinds of point-to-point, point-to-multipoint wireless data transmission systems, such as smart home, Internet of Things transformation, power load monitoring, distribution network...
  • Page 13: Notes

    During the warranty period, if the radio station is damaged due to the quality of the product itself rather than man-made damage or natural disasters such as lightning strikes, it will enjoy free warranty; please do not repair it by yourself. If there is a problem, please contact our company. Ebyte provides First-class after-sales service.
  • Page 14: Important Statement

    9. Important Statement Ebyte reserves the right of final interpretation and modification of all contents in this manual. Due to the continuous improvement of the hardware and software of the product, this manual may be changed without prior notice, and the latest version of the manual shall prevail.
  • Page 15: About Us

    E95-DTU(433C30-485) User Manual About us Technical support: support@cdebyte.com Documents and RF Setting download link: https://www.cdebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------- Phone: +86 028-61399028 Web: https://www.cdebyte.com Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China...

This manual is also suitable for:

433c30-485

Table of Contents