5.7. Transceiver Length and Sub-packing Mode

Model
E32-DTU (900L30)-V8
★ Note:
1. When the receiving data is more than a single packet capacity, the beyond part will be automatically assigned to
the second transmission until it is completed;
2. The data transceiver can not receive data which is more than the buffer capacity;

6. Operating mode

DTU has four operating modes, if low power consumption is not required, normal communication is recommended to
configure the data transceiver for the normal mode (mode 0);
The factory default is normal mode (mode 0).
Categories
Mode 0
Normal Mode
Mode 1
Wake-up Mode
Mode 2
Power-saving Mode
Mode 3
Sleep Mode
★ Note: no need to care about the wake-up mode (mode 1) and power saving mode (mode 2) if it doesn't request low
power consumption.
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd
Buffer
512Byte
M1
ON
ON
OFF
OFF
E32-DTU (900L30)-V8_User Manual_EN
Sub-package
Automatically send 58 bytes per package
M0
Description
Open UART and RF,transparent transmission
ON
Air wake-up mode, the packet comes with a
OFF
wake-up code,
The air wake-up receive mode, saving receive
ON
power, the mode can not be transmitted
Parameter setting using the configuration
OFF
is on
software
10