  • Page 1 E70-433NW30S User Manual 433MHz 1W Star Network SMD Wireless Module...
  • Page 2: Table Of Contents

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual CONTENT OVERVIEW................................2 1.1 INTRODUCTION..............................2 1.2 F ..................................2 EATURES SPECIFICATION AND PARAMETER......................3 2.1 L .................................3 IMIT PARAMETER 2.2 O ..............................3 PERATING PARAMETER 3 SIZE AND PIN DEFINITION..........................4 4 CONNECT TO MCU..............................7 5 FIRMWARE TRANSMITTING MODE........................7...
  • Page 3: Overview

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 1. Overview 1.1 Introduction E70-433NW30S is the star network module, operating at 433MHz, based on originally imported TI CC1310 and 15.4-Stack protocol, with coordinator and terminal as a whole. The module features with long range and high-speed transmission modes.
  • Page 4: Specification And Parameter

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 1.3 Application Home security alarm and remote keyless entry;  Smart home and industrial sensors;  Wireless alarm security system;  Building automation solutions;  Wireless industrial-grade remote control;  Health care products;...
  • Page 5: Size And Pin Definition

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Main parameter Description Remark Test condition:clear and open area, antenna gain: 5dBi, Distance for reference 6500m antenna height: 2.5m,air data rate: 5kbps TX length Transmission mode specification See transmission mode for details...
  • Page 6 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Pin item Pin direction Application Ground Ground electrode Ground Ground electrode Ground Ground electrode Reserved pin Reserved, to be floated Reserved pin Reserved, to be floated Reserved pin Reserved, to be floated...
  • Page 7 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual before transmission and pulled up after success. It can be configured as drain open circuit output or push-pull output. When it is used, a 1K protection resistor should be connected externally in series (it can be suspended).
  • Page 8: Connect To Mcu

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 4 Connect to MCU Description(STM8L MCU) The UART module is TTL level., please collect with MCU. For some MCU works at 5VDC, it may need to add 4-10K pull-up resistor for the TXD & AUX pin.
  • Page 9: Long Address Transmission

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Node B address 00 02 AA BB CC Node C address 00 03 AA BB CC 5.3 Long address transmission Format Values Coordinator short address transmission format: short address + valid data 00 00 00 00 00 00 00 00 00 or FF FF FF FF FF FF FF FF are broadcast address;...
  • Page 10: Link Description

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 【Indication of UART output】can be used to wake up external MCU. 【Indication of wireless transmitting】 1.The length of the buffer is 512 bytes, and the single packet must not exceed 128 bytes, when Aux=1, users can transmit data continuously within 128 bytes.
  • Page 11: Ack Description

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 6.3 ACK description The ACK pin is used to indicate the status of the last user’s data transmission. Before transmitting, the pin is pulled  low. After the transmission is successful, the pin is pulled high. The user can use this pin state to judge if the data has arrived successfully.
  • Page 12: Normal Node

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Long address transmission. When configured to long address transmission, the user must specify the long address before sending data. 7.2.Normal node If the user configures the operating mode 4,(M0=0,M1=1) or the user configures the operating mode as 1, the module works in the normal node mode.
  • Page 13: Quick Start

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 8.Quick start 8.1 Communication between normal node and coordinator Coordinator configuration Open the serial port assistant, select the serial port corresponding to the device, and set the serial port parameters (default is 115200, 8N1) Enter "+++"...
  • Page 14 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual shown in Figure 3: Figure 3 Normal node configuration Open the serial port assistant and select the serial port corresponding to the device. Set the baud rate to 115200, the data bit to 8 bits, the parity bit to none, the stop bit to 1 bit, and the flow control is disabled, open the serial port.
  • Page 15 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Figure 6 Network transmission data transmission When the configuration is complete, the coordinator restarts and the DIO11 pin is asserted low, indicating that the coordinator has started and is running. After an normal node device starts up, it will have a network access time of 10 to 20 seconds.
  • Page 16: Atc Command

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 9. AT Command When the serial port enters AT mode, it needs to open the serial port assistant, set the serial port (default parameter) baud rate 115200, data bit 8 bit, stop bit 1 bit, open the serial port, input "+++" without carriage return. All parameter settings will reply "\r\n+OK\r\n".
  • Page 17 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 2, Dormant Node; 3, Sleep mode; 4, (factory default), dial switch control Example:AT+ WMCFG =4 Note: 1. After setting a new mode, it needs to be reset or power off and restart...
  • Page 18 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual (This instruction is valid for coordinator only) Value:0~2 0:Input Broadcast(Only the coordinator works) 1:Input Short Address+Data (0x0000 0xfff) are broadcast address 2:Input Long Address+Data (0x000000000000 0xffffffffffffffff)are broadcast address Example:AT+TFICFG=0 AT+TMCFG Setting/Querying transport mode configuration (reboot valid)
  • Page 19 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual (reboot valid) Description: Gets the reboot parameter configuration AT+RSCFG=? Response: RSCFG:0 Description: Value:0 or 60~65535(S) AT+RSCFG=Value When the value less than 60s, the system judges 60, equals 0s, does not restart Example:AT+RSCFG=0 Note: This parameter can be used for node disconnection detection.
  • Page 20 Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Example:AT+UPCFG=0 AT+PWCFG Setting /Querying the power parameter(reboot valid) Description: Gets the power parameter AT+PWCFG=? Response: PWCFG:3 Description: Value:0~3 0:Polar Altitude AT+PWCFG=Value 1:High 2:Medium 3:Low Example:AT+ PWCFG=3 AT+IOCFG Setting /Querying the IO parameter Description:...
  • Page 21: Hardware Design

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Example:AT+ECHO=1 Note: This setting only applies when the power is turned on. After the restart, the default settings are restored and the echo is enabled by default. AT+VER Reading the version number...
  • Page 22: Faq

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the  margin, so the whole machine is beneficial for long-term stable operation.;...
  • Page 23: Module Is Easy To Damage

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 11.2 Module is easy to damage Please check the power supply source, ensure it is 2.0V~3.6V, voltage higher than 3.6V will damage the module.  Please check the stability of power source, the voltage cannot fluctuate too much.
  • Page 24: Reflow Soldering Curve

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual 12.2 Reflow Soldering Curve 13. E70 Series Frequency Tx power Distance Size Model No. Data Rate Package Interface E70-433NW30S 433M 2.5k~168k 24 * 38.5 IPEX/Stamp hole E70-433NW14S 433M 2.5k~168k 16 * 26 IPEX/stamp hole 14.
  • Page 25: Package For Batch Order

    Chengdu Ebyte Electronic Technology Co,;Ltd E70-433NW30S user manual Frequen Gain Model No. Type Interface Height Function feature cy Hz Cable Built-in flexibility,FPC soft TX433-NP-4310 Soft PCB antenna 433M SMA-J 43.8*9.5mm antenna TX433-JW-5 Rubber antenna 433M SMA-J 50mm Flexible &omnidirectional TX433-JWG-7...
  • Page 26: Revision History

    2020-10-15 About us Technical support: support@cdebyte.com Documents and RF Setting download link: www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------------------ Fax: 028-64146160 Web: www.ebyte.com Address: Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China Chengdu Ebyte Electronic Technology Co,;Ltd...