If the coordinator has associated more than 200 devices and wants to continue associating new devices, you need to
call the AT+CLINFO command to clear the current network information.
The average power consumption of low power nodes depends on the wake up period of user configuration. The large r
the cycle, the lower the power consumption, but the delay of receiving coordinator will be even higher.
Low-power node cannot receive broadcast data which transmitted by the coordinator
The system will be reset if the node is powered on for more than 60 seconds and it has not yet entered the network.
When node PANID is set to 0Xffff (65535), the node can join any network, otherwise it will only be able to join the
same network as its PANID.