Ebyte E70-DTU User Manual page 15

Hide thumbs Also See for E70-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co,;Ltd
AT+RSCFG=?
AT+RSCFG=Value
Example:AT+RSCFG=0
Note: This parameter can be used for node disconnection detection. It is recommended to open it.
AT+UBCFG Setting /Querying the baud rate parameter (reboot valid)
AT+UBCFG=?
12
AT+UBCFG=Value
Example:AT+UBCFG=7
AT+UPCFG Setting /Querying the device parity parameter(reboot valid)
AT+UPCFG=?
13
AT+UPCFG=Value
Example:AT+UPCFG=0
AT+PWCFG Setting /Querying the power parameter(reboot valid)
AT+PWCFG=?
14
AT+PWCFG=Value
Example:AT+ PWCFG=3
AT+IOCFG Setting /Querying the IO parameter
AT+IOCFG=?
15
AT+IOCFG=Value
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
13
Description:
Gets the reboot parameter configuration
Response:
RSCFG:0
Description:
Value:0 or 60~65535(S)
When the value less than 60s, the system judges 60, equals 0s, does not restart
Description:
Obtains the baud rate parameter
Response:
UBCFG:7
Description:
Value:0~7
0:1200
1:2400
2:4800
3:9600
4:19200
5:38400
6:57600
7:115200
Description
Gets the device parity parameter
Response:
UPCFG:0
Description:
Value:0~2
0:None
1:Odd parity
2:Even parity
Description:
Gets the power parameter
Response:
PWCFG:3
Description:
Value:0~3
0:Polar Altitude
1:High
2:M edium
3:Low
Description:
Gets the IO parameter
Response:
IOCFG:0
Description:
Value:0 or 1
0:Push-pull
1:open-drain
E70 -DTU (433NW30) user manual