Chengdu Ebyte Electronic Technology Co,;Ltd
AT+ TFOCFG=?
AT+ TFOCFG=Value
Example:AT+ TFCFG=0
AT+ TFICFG Setting/Querying input transmission format configuration (reboot valid)
AT+ TFICFG=?
7
AT+ TFICFG=Value
(This instruction is valid for coordinator
only)
Example:AT+TFICFG=0
AT+TMCFG Setting/Querying transport mode configuration (reboot valid)
AT+TMCFG=?
8
AT+TMCFG=Value
Example:AT+TM CFG=0
Note: The coordinator and node should have the same transmission mode before they can access the network.
AT+ PIDCFG Setting/Querying PANID configuration(reboot valid)
AT+PIDCFG=?
9
AT+PIDCFG=Value
Example:AT+PIDCFG=65535
Note: The node can only join the same network as its PANID (any network can be added when it is configured as 65535)
AT+ DM CFG Setting/Querying dormancy time configuration(reboot valid)
AT+DM CFG=?
10
AT+DM CFG=Value
Example:AT+DM CFG=0
AT+RSCFG Setting/Querying the reboot parameter configuration
11
(reboot valid)
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co,;Ltd
12
Description:
Gets output format configuration
Response:
TFOCFG:0
Description:
Value:0~7
0:Output: valid data (transparent transmission))
1: Output: Valid Data +Long Address
2:Output: Valid Data +Short Address
3:Output: Valid Data+RSSI
4:Output:Valid Data+Long Address+Short Address
5:Output:Valid Data+Long Address+RSSI
6:Output:Valid Data+Short Address+RSSI
7:Output:Valid Data+Long Address+Short Address+RSSI
Description:
Gets input transmission format configuration
Response:
TFICFG:0
Description:
Value:0~2
0:Input Broadcast(Only the coordinator works)
1:Input Short Address+Data (0x0000 0xfff) are broadcast address
2:Input Long Address+Data
0xffffffffffffffff)are broadcast address
(0x000000000000
Description:
Gets transport mode configuration
Response:
TM CFG:0
Description:
Value:0 or 1
0:Long Range mode,LRM
1:Standard transmission mode,GFSK
Description:
Gets PANID configuration
Response:
PIDCFG:65535
Description:
Value:0~65535
Description:
Gets dormancy time configuration
Response:
DM CFG:0~60
Description: Configure wakeup period of sleep node
Value: dormant time, per unit second (S). 0~60 S.
Note: When configured as 0, the node will never wake up, that is, the node
cannot receive data but can upload data
E70 -DTU (433NW30) user manual