Download Print this page

Opening Clearances - Element4 Tenore 100 GSB Installation, Operation And Owner's Manual

Direct vent gas fireplaces
Hide thumbs Also See for Tenore 100 GSB:

Advertisement

TYPICAL CLEARANCE DIAGRAMS
The total area of the air openings must be maintained. The location of the openings must allow for the free movement of air and
must not allow excessive warm air to build up within the chase.
The top of the Air Outlet must be no more than 1" (25 mm) down from the chase ceiling.
The minimum distance from the bottom of the appliance to the room ceiling is 72" (1830
Figure 17
Minimum Distances
Room ceiling to
A
appliance bottom
Chase ceiling to top
B
of Air Outlet
Figure 18
Element4 Gas Fireplaces Rev #05112020
CLEARANCES
72"
1830
mm
1"
25
mm
Figure 19
mm)
B
B
Air Outlet
A
Minimum Required Air Opening Sizes
Square
Model
Inches
Tenore 100 GSB
145
Lucius 100I GSB
17
.
Air Inlet
Air Outlet
Square
Square
Square
Centimeters
Inches
Centimeters
936
145
EuropeanHome.com
936

Advertisement

loading

This manual is also suitable for:

Lucius 100 gsb