Advertisement

Quick Links

Product
Trisore 95
Information
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit
être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces Rev# 07302019
Video
Installation, Operation and
Owner's Manual
Bidore 95
Modore 95
Trisore 95
Direct Vent
Gas Fireplaces
Une surface vitrée chaude
peut causer des brûlures.
Laisser refroidir la surface
vitrée avant d'y toucher.
Ne permettez jamais á un enfant
de toucher la surface vitrée.
AVERTISSEMENT:
INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité à la
lettre pourrait entraîner de graves blessures , la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d'allumer d'appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l'entretien doivent être effectués par un
installateur qualifié, une agence de service ou le fournisseur
de gaz.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
4006611
July 2019
EuropeanHome.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bidore 95 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Element4 Bidore 95

  • Page 1 INSTALLER: Leave this manual with the appliance. INSTALLATEUR: Laissez cette notice avec l’appareil. CONSUMER: Retain this manual for future reference. CONSOMMATEUR: Conservez cette notice pour consultation ultérieure. July 2019 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com 4006611...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information ..................... 3 Key Installation Points ......................6 User Information ........................7 Specifications and Dimensions ..................8 Bidore 95 MKII Modore 95 MKII Trisore 95 MKII Parts of the Fireplace Clearances ..........................14 Locating the Fireplace...
  • Page 3: Important Safety Information

    Do not place furniture or other objects within 36” of the fireplace glass. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Element4 direct vent gas fireplace appliance. INSTALLER: Leave this manual with the appliance.
  • Page 4 Canada, consult with the local authority having The glass must only be removed by a qualified person. jurisdiction for gas product installations to determine their Gloves should be worn when removing the glass. specific requirements for high altitude installations. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 5 DO NOT USE abrasive cleaners on the panels. DO NOT the nearest 1/16” when converted. If greater accuracy is ATTEMPT to clean the glass panels when they are hot. required, use the metric dimensions. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 6: Key Installation Points

    GAS PRESSURES Gas pressures MUST be read with a manometer and confirmed with what is required in the installation manual. FINISHING Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 7: User Information

    WARMTH AND BEAUTY - HOW IT WORKS The Element4 fireplaces are direct vent fireplaces and, as such, the intake and exhaust are both handled through the vent pipe. The fireplace also provides convection air to your room. The illustration shows one of the unique features of the Element4 fireplaces - its use of warm, convection air flow.
  • Page 8: Specifications And Dimensions

    Gas Fireplaces” by Intertek Group. (Figure 3) A sample listing label image is shown above. A metal listing label is attached to every Element4 fireplace and contains important certification information. The listing label must not be removed from the fireplace.
  • Page 9 BIDORE 95 11/2017 Bidore 95 RC shown (Bidore 95 LC is a mirror image) Figure 7 This information is for reference only. Please consult the Installation Manual for all details prior to making any design decisions. Conversions from millimeters are rounded to the nearest fraction. A DWG file is available at www.europeanhome.com www.EuropeanHome.com...
  • Page 10 401/16 1017 65/8 271/2 131/2 81/2 131/4 Unit Weight Plan View Pounds Kilograms 100.5 L Elevation Front Elevation R Elevation Figure 8 A downloadable DWG file is available at www.europeanhome.com for dimensions not shown. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 11 This information is for reference only. Please consult the Installation Manual for all details prior to making any design decisions. Conversions from millimeters are rounded to the nearest fraction. A DWG file is available at www.europeanhome.com A downloadable DWG file is available at www.europeanhome.com for dimensions not shown. www.EuropeanHome.com PDE4T95MKII-170807 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 12: Parts Of The Fireplace

    Finish Trim - hides the Glass Clamps Glass Rope Gaskets - holds the Glass Panel in place (2 ea. - Modore 95, 3 ea. - Bidore 95, 4 ea. - Trisore 95) Vent Collar - accepts the 5” x 8” venting adapter (included) Relief Door - part of the safety system.
  • Page 13 Finish Trim - hides the Glass Clamps Glass Rope Gaskets - holds the Glass Panel in place (2 ea. - Modore 95, 3 ea. - Bidore 95, 4 ea. - Trisore 95) Vent Collar - accepts the 5” x 8” venting adapter (included) Relief Door - part of the safety system.
  • Page 14: Clearances

    VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT IMPEDE THE FULL OPERATION OF THE RELIEF DOORS. IT IS YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION PROCESS. REMOVE AND DISPOSE OF ALL WRAPS AND TIES. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 15: Clearances To Combustibles

    We recommend that the fireplace be set into its final location before building the enclosure. Please refer to the “Reduced Clearance to Existing Combustible Wall” section for use of combustibles inside of the above clearances. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 16 (TYPICAL) Mantel Depth NON COMBUSTIBLE 12”/300 mm MATERIAL CONSTRUCTION BEAMS NON- COMBUSTIBLE (TYPICAL) DETAIL C ETAIL C 1”/25 mm ALE 1 : 10 TOP OF FIREPLACE OPENING GLASS CONVECTION GAP Figure 17 Figure 18 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 17 Air Outlet Area by Model Room ceiling to 72” Square Square Model Inches Centimeters appliance bottom 1830 Modore 95 MKII Room ceiling to top of 1” Air Outlet Bidore 95 MKII Figure 20 Trisore 95 MKII Figure 21 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 18: Gas And Electric

    Remove batteries after use to avoid battery corrosion. Battery corrosion will damage the receiver. Electrical work must be performed by a qualified, licensed electrician. WARNING All wiring shall be in compliance with all local, city, and state codes. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 19: Venting

    Pro-Form (BDM - Bernard Dalsin Manufacturing) Direct-Temp (Selkirk Corporation) AmeriVent Direct Vent (Hart & Cooley Inc.) Ventis Direct Vent (Olympia Chimney Supply, Inc.) Figure 23 Please visit www.europeanhome.com/technical-support/ for the power venting installation manuals Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 20 Calculate the Total Vertical Section by adding up all vertical upward sections in your specific vent design. CALCULATING THE TOTAL HORIZONTAL SECTION (THS) Calculate the Total Horizontal Section by adding up all horizontal sections in your specific vent design. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 21 Please use the graph above (Figure 28) to determine if you will need to use a restrictor. Loosen these two Phillips head screws to slide the restrictor on/off. Figure 29 Figure 30 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 22: Venting Charts

    VENTING VENTING CHARTS HORIZONTAL TERMINATIONS & RESTRICTOR USE Total Vertical Section Total Horizontal Section Figure 31 VERTICAL TERMINATIONS & RESTRICTOR USE Total Vertical Section Total Horizontal Section Figure 32 Figure 33 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 23 VENTING CLEARANCES HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS Figure 34 Figure 35 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 24 National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada. Figure 36 Figure 37: Termination Heights A second termination may be no closer than 12”/305 Figure 38: Multiple Termination Clearance Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 25: Enclosing The Fireplace

    Figure 39: * The listed brand names are trademarks of their respective companies. Skamol Americas, Inc. (844) 475-2665 E-mail: skamotec225@skamol.com www.skamotec225.com Promat Inc. (865) 681-0155 E-mail: sales@promat.us www.promat.us/en James Hardie Building Products (888) 542-7343 www.jameshardie.com Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 26 ENCLOSING the FIREPLACE BUILDING THE ENCLOSURE/FRAMING A safe installation of your Element4 fireplace requires that three things be clearly understood. 1. Most important, these fireplaces are NOT zero-clearance fireplaces. Unlike zero-clearance fireplaces, there is not an outer metal box around the Element4 fireplaces which increases the framing dimensions.
  • Page 27 OMbuSTIbLE hIELd INIShEd OMbuSTIbLE hIELd INIShEd Figure 41 2”/50 Minimum Air Gap MUST BE MAINTAINED 1”/25 Minimum Air Gap MUST BE MAINTAINED Figure 40 OMbuSTIbLE hIELd INIShEd hIELd INIShEd OMbuSTIbLE Figure 42 Figure 43 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 28 James Hardie Building Products HardieBacker® 500 1/2” Cement Board 1/2” (12 James Hardie Building Products HardieBacker® 1/4” Cement Board 1/4” (6 Figure 44 Fireplace Trim Figure 46 Minimum Wall Thickness = 1/2”/12 Figure 45 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 29 When enclosing the Bidore 95 fireplace there is a minimum clear area which must be maintained. Nothing except the Bidore 95 may be within this area. When enclosed, the Bidore 95 MKII LC is against the left wall or the Bidore 95 RC is against the right wall. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL.
  • Page 30 (A, B and C) shown above. Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. recommend that the fireplace be set into its final location before building the enclosure. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 31 (A, B and C) shown above. Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. recommend that the fireplace be set into its final location before building the enclosure. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 32 Figure 50: Modore 95 with Air Outlets in Wall Figure 51: Modore 95 with Air Outlet in Reveal Figure 52: Bidore 95 with Air Outlets in Wall Figure 53: Bidore 95 with Air Outlet in Reveal Figure 54: Trisore 95 with Air Outlets in Wall...
  • Page 33 Figure 57: Modore 95 shown. The Bidore and Trisore models have the same requirement. Use the adjustable feet to ensure that the fireplace is level prior to enclosing it. Do NOT lift the fireplace by the face frame but by the bottom of the cabinet. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 34: Rough Opening Dimensions

    When measured at the level of the feet, the controls will reach no farther from 28” 49” the cabinet edge than shown at left. 1244 The drawing is not to scale. 51” Figure 59 1295 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 35 Replace the white door/frame cover onto the frame and secure it with the four bolts. Figure 62 Figure 63 Fit the gas control tab into the bracket on Tighten the bolt through the mounting the Access Door frame. bosses. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 36 Once the system stays lit for at least one full minute, turn the fireplace off, fix the glass panels in place and operate the fireplace for at least 45 minutes to ensure the system works properly when heated. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 37: Installing The Fire Media

    - two bags of black chips - one bag of grey chips With the embers scattered across the burner and hearth panel, lay the logs in the following sequence... Figure 66 Figure 67 Figure 68 Figure 69 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 38 C shows the 2 thermocouple area (Figure __) clear of media (Figure __). 2nd Thermocouple Pilot Assembly Figure 71 To see how to arrange media in an Element4 fireplace please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 39: Screen Installation

    Place the two Lower Tabs on the trim, with the short side against the glass, about 2-3” from each corner of the glass. Place a magnet on the front of each tab. Figure 79 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 40 Figure 81 This is what the screen will look like when it is attached correctly to the top Upper Tabs (viewed from inside of the standoff frame). Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 41 This is what the screen will look like when it is attached correctly to the Lower Tabs (viewed between the screen and the glass). Figure 83 The screen is installed properly in the photo above. Ensure that all magnets are in the correct position and the tabs are secured. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 42: Operating The Fireplace

    ON when the fireplace is Figure 85 turned on. Note! For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 43 OPERATING the FIREPLACE OPERATING the FIREPLACE 10 BUTTON REMOTE CONTROL Multi-Burner Status Figure 85 Figure 87 Figure 86 Figure 88 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com Element4 Gas Fireplaces EuropeanHome.com Element4 Gas Fireplaces IGE4-2301-181107...
  • Page 44 Figure 89 Figure 90 Figure 91 Figure 92 Figure 93 NOTE: There is a 2 min delay before the next ignition is possible. Figure 95 Figure 94 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com Element4 Gas Fireplaces IGE4-2301-181107 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 45 OPERATING the FIREPLACE OPERATING the FIREPLACE OPERATING the FIREPLACE Figure 96 Figure 97 Figure 99 Figure 98 Figure 100 Figure 102 Figure 101 Figure 104 Figure 103 Element4 Gas Fireplaces Element4 Gas Fireplaces EuropeanHome.com IGE4-2301-181107 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 46 LED Mode can only be used for Club and Summum Series replaces. Press the button to turn on, dim, and turn o LED burner function. To change LED color (Club Series only) you must use the ProControl App. Element4 Gas Fireplaces IGE4-2301-181107 Element4 Gas Fireplaces EuropeanHome.com Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 47 • CHILD PROOF (To activate press buttons simultaneously. displayed and the handset is rendered inoperable (except for off functi- on). • PROGRAM MODE • THERMOSTATIC MODE (also deactivates Program Mode) • ECO MODE • MULTI-BURNER FEATURE • COUNTDOWN TIMER Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 48 Since it is a metal fireplace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction of these metals. The premium materials and build quality of your fireplace will keep these sounds to a minimum. Figure 110 To see an Element4 fireplace starting and running normally please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 49: Maintenance

    Figure 113 Remove the ROPE GASKET starting from one end down to the other end To see how to remove the glass from an Element4 fireplace please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ Figure 114 The ROPE GASKET will be removed for any remaining sides.
  • Page 50 Step 4. While ensuring that the glass panels are tight and square to each another, carefully install the remaining rope gaskets. PROPERLY PLACE ROPE GASKET(S) AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE! Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 51: Burner

    The pilot has two distinct flames, one engulfing the thermocouple on its left, the other reaching across to the burner. The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum. Figure 115 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 52: Thermocouple

    MAINTENANCE THERMOCOUPLE MAINTENANCE The Element4 fireplaces have two thermocouples; one next to the pilot and one opposite the pilot side of the burner. The completeness and operation of both must be checked. A qualified installer must confirm that both thermocouples are in place and not damaged.
  • Page 53: Replacement Parts

    Item Description (Required) (Each) Front Glass (Long) E4-GLASS-95-FRONT/LUC2/3 Side Glass E4-GLASS-140-95-SIDE Safety Screen E4-SS-BID1005R-MKII All Tabs with Magnets (kit) E4-SA-SS-HWK-4/12 Lower and Side Trim Repl-E4-CP-TRIM-BID-95-MKII Foot with nut Repl-E4-CP-FT Hearth Panel Repl-E4-CP-HEARTH-95-MKII Figure 118 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 54 Modore 95 Quantity Part Number Item Description (Required) (Each) Glass E4-GLASS-95-FRONT/LUC2/3 Safety Screen E4-SS-MOD1005R-MKII All Tabs with Magnets (Kit) E4-SA-SS-HWK-3/9 Lower and Side Trim Repl-E4-CP-TRIM-MOD-95-MKII Foot with nut Repl-E4-CP-FT Hearth Panel Repl-E4-CP-HEARTH-95-MKII Figure 120 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 55 Item Description (Required) (Each) Front Glass (Long) E4-GLASS-95-FRONT/LUC2/3 Side Glass E4-GLASS-140-95-SIDE Safety Screen E4-SS-TRI1005R-MKII All Tabs with Magnets (kit) E4-SA-SS-HWK-5/15 Lower and Side Trim Repl-E4-CP-TRIM-TRI-95-MKII Foot with nut Repl-E4-CP-FT Hearth Panel Repl-E4-CP-HEARTH-95-MKII Figure 122 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 56 MAINTENANCE REPLACEMENT PARTS Figure 123 Figure 125 Figure 124 Quantity Item Description Part Number (Each) (Required) Repl-E4-GS-PABT-01 Pilot Assembly Repl-E4-GS-IGL-01 Ignitor Rod Repl-E4-GS-1T-01 1st Thermocouople 2nd Thermocouple Repl-E4-GS-2TC-mount-01 (w/ mount) Figure 126 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 57 MAINTENANCE REPLACEMENT PARTS Figure 127 Quantity Part Number Item Description (Required) (Each) Gas valve Repl-E4-GS-GV-01 Receiver E4-GS-CM-Wifi-02 (Control Module) 8 button Remote E4-GS-RC-Wifi Figure 128 Figure 129 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 58: Warranty

    Customer: Please retain this information. Model Modore 95 Bidore 95 Trisore 95 (check one) Purchased From Date of Purchase Installed By Date of Installation Fireplace Serial Number Fuel Type Total Venting Horizontal Total Venting Vertical Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 59: Massachusetts Certification

    Gas Fitters has issued approval number G3-0116-219  for this appliance. The following must be observed when installing the Element4 fireplaces within the Commonwealth of Massachusetts: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole...
  • Page 60: Troubleshooting Flowchart

    Motor not operating Replace gas valve. properly. Micro switch not Replace gas valve. operating properly. 2nd thermocouple Confirm integrity of 2nd thermocouple and not connected connection. (continued) Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com I:\DEPARTMENTS\Technical Support\Troubleshooting\Guides\20181205_Troubleshooting Flow Chart_E4_8btn Edition.indd...
  • Page 61 Short between interrupter block and TC- Check connection to interrupter block. cable. Sparking stops after pilot is lit. Electronic measuring amplifier defective. Replace the receiver. (continued) Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 62 Turn the control knob to “ON” position, a Manual knob is in the “MAN” position. positive latch is required. Main burner is lit. Confirm correct gas pressure. Increase pilot Pilot flame is too low. flame if necessary. (continued) Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 63 Test the batteries, replace if necessary. Receiver batteries low. Quality 1.5V AA alkaline recommended. Magnet unit drops Ensure magnet unit is operating while motor turns. Test the receiver output to the magnet unit. normally. Receiver makes 3 beeps. (continued) Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 64 Check venting for complete integrity. Reduce the primary air opening until flames have blue Too much primary air. base and yellow upper two-thirds. Flames are stable but too small and blue. NORMAL OPERATION Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 65 APPENDIX TWO Remote/Receiver Combinations Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 66 DOWN • Decrease the flame height: Press and hold the DOWN button. • For fine adjustment tap the UP or DOWN button as necessary. • Turn fireplace OFF: Press the ON/OFF button. Figure 131 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 67 Frequent ON and OFF cycles will limit life expectancy of the valve and will increase battery consumption. The fireplace should be powered by the AC adapter for improved reliability and customer satisfaction. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 68 Insert the short black glass using the same procedure as the long black glass. The short glass edge should overlap the long glass edge. (This step is for Modore and Bidore Models only) Figure 136 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 69 No communication between receiver and Wi-Fi Contact service No control possible by the electronics module Contact service No temperature display in the App • No hand transmitter connected “N.a. ” in the App • Batteries hand transmitter empty Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 70 2x 1.5 V AAA 4 sec. No reaction from the fireplace No or bad connection between the receiver and Interrupted responses hand transmitter No electronic control No voltage on the receiver Low communication range, AC adapter Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 71 Try to keep jammers as far away as possible devices can not connect via the 5GHz band, the ProControl from the router. Neighboring wireless networks also play a module is not suitable for 5GHz band. role in the Wi-Fi area. Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 72 Learances KEY INSTALLATION pOINTS 6 WALL ACCESS dOOR 34 LISTING LAbEL 8 WALL SWITCh Appendix Three WARRANTY 57 MAINTENANCE urner iLot herMocoupLes MANTELS 16 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...
  • Page 73 Imported and distributed in North America by: EUROPEAN HOME a division of Europa Ja, Inc. 30 Log Bridge Road Building 300 - Suite 303 Middleton, MA 01949 www.europeanhome.com IGE45II-181029 Element4 Gas Fireplaces Rev# 07302019 EuropeanHome.com...

This manual is also suitable for:

Modore 95Trisore 95

Table of Contents