Download Print this page

Element4 Modore 95 MKII Installation, Operation And Owner's Manual

Direct vent gas fireplaces

Advertisement

Quick Links

Product
Trisore 95 MKII
Information
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
Une barrière conçu pour réduire le risque de brûlure par le verre de visualisation chaude est fournie avec cet appareil et doit
être installé pour la protection des enfants et autres personnes à risque.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Element4 Gas Fireplaces
Video
Installation, Operation and
Owner's Manual
Modore 95 MKII
Bidore 95 MKII
Trisore 95 MKII
Direct Vent
Gas Fireplaces
Une surface vitrée chaude
peut causer des brûlures.
Laisser refroidir la surface
vitrée avant d'y toucher.
Ne permettez jamais á un enfant
de toucher la surface vitrée.
AVERTISSEMENT:
INCENDIE OU D'EXPLOSION
Le non-respect des avertissements de sécurité à la
lettre pourrait entraîner de graves blessures , la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
• Ne pas tenter d'allumer d'appareil.
• Ne touchez á aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bátiment ou vous trouvez.
• Quitter immédiatement le bâtiment.
• Appelez immédiatment votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz
appelez le service des incindies.
- Installation et l'entretien doivent être effectués par un
installateur qualifié, une agence de service ou le fournisseur
de gaz.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour
consultation ultérieure.
1
4006611
May 2018
EuropeanHome.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Modore 95 MKII and is the answer not in the manual?

Questions and answers

Summary of Contents for Element4 Modore 95 MKII

  • Page 1 Installation, Operation and Owner’s Manual Modore 95 MKII Bidore 95 MKII Trisore 95 MKII Product Trisore 95 MKII Information Video Direct Vent Gas Fireplaces HOT GLASS WILL Une surface vitrée chaude CAUSE BURNS. peut causer des brûlures. DO NOT TOUCH GLASS Laisser refroidir la surface UNTIL COOLED.
  • Page 2: Table Of Contents

    Important Safety Information ..................... 3 Key Installation Points ......................6 User Information ........................7 Specifications and Dimensions ..................8 Bidore 95 MKII Modore 95 MKII Trisore 95 MKII Parts of the Fireplace Clearances ..........................14 Locating the Fireplace Placing the Fireplace...
  • Page 3: Important Safety Information

    Do not place furniture or other objects within 36” of the fireplace glass. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Element4 direct vent gas fireplace appliance. INSTALLER: Leave this manual with the appliance.
  • Page 4 Canada, consult with the local authority having The glass must only be removed by a qualified person. jurisdiction for gas product installations to determine their Gloves should be worn when removing the glass. specific requirements for high altitude installations. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 5 For convenience, the inches are rounded to DO NOT USE abrasive cleaners on the panels. DO NOT the nearest 1/16” when converted. If greater accuracy is ATTEMPT to clean the glass panels when they are hot. required, use the metric dimensions. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 6: Key Installation Points

    Gas pressures MUST be read with a manometer and confirmed with what is required in the installation manual. FINISHING A 1/8”/3 gap between the flange and the enclosing wallboard MUST be maintained to prevent cracking from heat expansion and contraction. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 7: User Information

    WARMTH AND BEAUTY - HOW IT WORKS The Element4 fireplaces are direct vent fireplaces and, as such, the intake and exhaust are both handled through the vent pipe. The fireplace also provides convection air to your room. The illustration shows one of the unique features of the Element4 fireplaces - its use of warm, convection air flow.
  • Page 8: Specifications And Dimensions

    A sample listing label image is shown Pilot Injector Marking  32.2 27.1 above. A metal listing label is attached to every Element4 fireplace and contains Efficiency 79.4% important certification information. The listing label must not be removed from the fireplace.
  • Page 9: Bidore 95 Mkii

    L Elevation Front Elevation Front Elevation Front Elevation R Elevation R Elevation R Elevation Bidore 95 RC shown. Bidore 95 LC is a mirror image. A downloadable DWG file is available at www.europeanhome.com for dimensions not shown. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 10: Modore 95 Mkii

    SPECIFICATIONS and DIMENSIONS MODORE 95 MKII Letter Inches Millimeters 77/8 3511/16 161/16 345/8 401/16 1017 65/8 271/2 131/2 81/2 131/4 Unit Weight Plan View Pounds Kilograms 100.5 L Elevation Front Elevation R Elevation A downloadable DWG file is available at www.europeanhome.com for dimensions not shown.
  • Page 11: Trisore 95 Mkii

    365/8 169/16 345/8 4011/16 1034 65/8 281/8 131 5/16 81/2 135/16 Unit Weight Pounds Kilograms Plan View 88.2 Front Elevation L Elevation R Elevation A downloadable DWG file is available at www.europeanhome.com for dimensions not shown. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 12: Parts Of The Fireplace

    SPECIFICATIONS and DIMENSIONS PARTS OF THE FIREPLACE The various parts of the 95 MKII Series fireplaces are shown below. These parts are typical of any Element4 fireplace. Table of Fireplace Parts Outer Frame Face- surrounds the glass panels, limits the non-combustible wall board and allows air in.
  • Page 13 Vent Collar - accepts the 5” x 8” venting adapter (included) Relief Door - part of the safety system. Do NOT block the operation. Pilot Assembly Upright Trim - (2 ea. - Modore, Bidore, Trisore 95) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 14: Clearances

    VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT IMPEDE THE FULL OPERATION OF THE RELIEF DOORS. IT IS YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION PROCESS. REMOVE AND DISPOSE OF ALL WRAPS AND TIES. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 15: Clearances To Combustibles

    These clearances are the same for ALL Element 4 Fireplaces, regardless of model. We reccomend that the fireplace be set into its final location before building the enclosure. Please refer to the “Reduced Clearance to Existing Combustible Wall” section for use of combustibles inside of the above clearances. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 16: Mantel Clearances

    OF GLASS CONSTRUCTION BEAMS COMBUSTIBLE INCHES (TYPICAL) Mantel Depth NON COMBUSTIBLE 12”/300 mm MATERIAL CONSTRUCTION BEAMS NON- COMBUSTIBLE (TYPICAL) DETAIL C ETAIL C 1”/25 mm ALE 1 : 10 TOP OF FIREPLACE OPENING GLASS CONVECTION GAP Element4 Gas Fireplaces EuropeanHome.com...
  • Page 17: Convection Clearances

    Air Outlet Area by Model Minimum Distances Square Square Model Room ceiling to 72” Inches Centimeters appliance bottom 1830 Modore 95 MKII Room ceiling to top of 1” Bidore 95 MKII Air Outlet Trisore 95 MKII Element4 Gas Fireplaces EuropeanHome.com...
  • Page 18: Gas And Electric

    Remove batteries after use to avoid battery corrosion. Battery corrosion will damage the receiver. Electrical work must be performed by a qualified, licensed electrician. WARNING All wiring shall be in compliance with all local, city, and state codes. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 19: Venting

    EXCELDirect (ICC - Industrial Chimney Company) Pro-Form (BDM - Bernard Dalsin Manufacturing) Direct-Temp (Selkirk Corporation) AmeriVent Direct Vent (Hart & Cooley Inc.) Ventis Direct Vent (Olympia Chimney Supply, Inc.) Please visit www.europeanhome.com/technical-support/ for the power venting installation manuals Element4 Gas Fireplaces EuropeanHome.com...
  • Page 20 Calculate the Total Vertical Section by adding up all vertical upward sections in your specific vent design. CALCULATING THE TOTAL HORIZONTAL SECTION (THS) Calculate the Total Horizontal Section by adding up all horizontal sections in your specific vent design. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 21 Loosen the screws on either side and slide the restrictor as desired. Do not modify the restrictor(s). Please use the graph above to determine if you will need to use a restrictor. Loosen these two Phillips head screws to slide the restrictor on/off. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 22: Venting Charts

    VENTING VENTING CHARTS HORIZONTAL TERMINATIONS & RESTRICTOR USE Total Vertical Section Total Horizontal Section VERTICAL TERMINATIONS & RESTRICTOR USE Total Vertical Section Total Horizontal Section Element4 Gas Fireplaces EuropeanHome.com...
  • Page 23: Venting Clearances

    VENTING CLEARANCES HORIZONTAL VENT TERMINATION CLEARANCES AND REQUIREMENTS Element4 Gas Fireplaces EuropeanHome.com...
  • Page 24 National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada. Termination Heights A second termination may be no closer than 12”/305 Multiple Termination Clearance Element4 Gas Fireplaces EuropeanHome.com...
  • Page 25: Enclosing The Fireplace

    James Hardie Building Products HardieBacker® 1/4” Cement Board 1/4”/6 * The listed brand names are trademarks of their respective companies Skamol Americas, Inc. (844) 475-2665 E-mail: skamotec225@skamol.com www.skamotec225.com Promat Inc. (865) 681-0155 E-mail: sales@promat.us www.promat.us/en James Hardie Building Products (888) 542-7343 www.jameshardie.com Element4 Gas Fireplaces EuropeanHome.com...
  • Page 26 1. Most important, these fireplaces are NOT zero-clearance fireplaces. Unlike zero-clearance fireplaces, there is not a metal box around the Element4 fireplaces. With no metal box there are no louvers to distract your view of the fire. However, we want the cooling advantage of a metal box so your site-built, non-combustible enclosure will substitute.
  • Page 27 ENCLOSING the FIREPLACE REDUCED CLEARANCE TO EXISTING COMBUSTIBLE WALLS OMbUSTIbLE hIELd INIShEd OMbUSTIbLE hIELd INIShEd 2”/50 Minimum Air Gap MUST BE MAINTAINED 1”/25 Minimum Air Gap MUST BE MAINTAINED OMbUSTIbLE hIELd INIShEd hIELd INIShEd OMbUSTIbLE Element4 Gas Fireplaces EuropeanHome.com...
  • Page 28 Skamol Skamotec® 225 Fireplace Building Board 11/2”/38 Promat PROMAFOUR® System 1/2”/12 5/8”/15 3/4”/18 James Hardie Building Products HardieBacker® 500 1/2” Cement Board 1/2”/12 James Hardie Building Products HardieBacker® 1/4” Cement Board 1/4”/6 Fireplace Trim Minimum Wall Thickness = 1/2”/12 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 29: Rough Opening Dimensions

    (A, B and C) shown above. Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. recommend that the fireplace be set into its final location before building the enclosure. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 30 When enclosing the Modore 95 MKII fireplace there is a minimum clear area which must be maintained. Nothing except the Modore 95 MKII may be within this area. When enclosed, the Modore 95 MKII is centered between the left and right enclosing walls. This minimum area MUST BE DEFINED BY NON-COMBUSTIBLE MATERIAL.
  • Page 31 (A, B and C) shown above. Your installation will use more than this minimum cabinet space in order to accommodate controls, venting, air openings, etc. recommend that the fireplace be set into its final location before building the enclosure. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 32: Convection Air Opening

    Outlet in Reveal Trisore 95 with Air Trisore 95 with Air Outlets in Wall Outlet in Reveal Air Outlet Area by Model Square Square Model Inches Centimeters Modore 95 MKII Bidore 95 MKII Trisore 95 MKII Element4 Gas Fireplaces EuropeanHome.com...
  • Page 33 The entire weight of the non-combustible walls must be borne by a structure other than the fireplace. Modore 95 MKII shown. The Bidore and Trisore models have the same requirement. Use the adjustable feet to ensure that the fireplace is level prior to enclosing it.
  • Page 34: Cold Climate Installation

    51” 1295 When measured at the level of the feet, the controls will reach no farther from 28” 49” the cabinet edge than shown at left. 1244 The drawing is not to scale. 51” 1295 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 35 Replace the white door/frame cover onto the radius of less than 2”/50 frame and secure it with the four bolts. Tighten the bolt through the mounting Fit the gas control tab into the bracket on bosses. the Access Door frame. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 36 45 minutes to ensure the system works properly when heated. DO NOT OPERATE THE BURNERS WITH THE GLASS OFF FOR MORE THAN THREE (3) MINUTES OR DAMAGE WILL OCCUR! Element4 Gas Fireplaces EuropeanHome.com...
  • Page 37: Installing The Fire Media

    - two pine cones - seven logs - two bags of black chips - one bag of grey chips With the embers scattered across the burner and hearth panel, lay the logs in the following sequence... Element4 Gas Fireplaces EuropeanHome.com...
  • Page 38 (actual burner pilot assembly and thermocouple location may vary depending on model) (grey stones shown here) C shows the 2 thermocouple area (below) clear of media (above). 2nd Thermocouple Pilot Assembly To see how to arrange media in an Element4 fireplace please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ Element4 Gas Fireplaces EuropeanHome.com...
  • Page 39: Screen Installation

    SCREEN INSTALLATION MODORE 95 MKII BIDORE 95 MKII TRISORE 95 MKII Upper Tabs Upper Tabs Upper Tabs Lower Tabs Lower Tabs Lower Tabs Magnets Magnets Magnets Long Screen Long Screen Long Screen Short Screen Short Screen Short Screen Lower Tab...
  • Page 40 Place the two Upper Tabs on the inside of the top stand off frame. One magnet will be hidden, attached to the standoff frame. The other magnet will be exposed to attach to the screen. This is what the screen will look like when it is attached correctly to the top Upper Tabs (viewed from inside of the standoff frame). Element4 Gas Fireplaces EuropeanHome.com...
  • Page 41 This is what the screen will look like when it is attached correctly to the Lower Tabs (viewed between the screen and the glass). The screen is installed properly in the photo above. Ensure that all magnets are in the correct position and the tabs are secured. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 42: Operating The Fireplace

    OFF when the fireplace is turned off and to ON when the fireplace is turned on. Note! For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 43 WARNING 5. Press buttons simultaneously. Min- When pilot ignition is confirmed, motor turns automatically to maximum utes flash. flame height. 6. To select minutes press button. 7. To confirm press buttons simulta- neously or wait. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 44 NOTE: At end of countdown time period, the fire turns off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maxi- mum countdown time is 9 hours and 50 minutes. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 45 , , , , , , , . temperature flashes. 6. To confirm press button. 2. To adjust set temperature press but- ton. 3. To confirm press button or wait. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 46 • Daily Timer: Unique on and off times may be set for a single day of the week, for multiple days of the week, or for every day of the week. • Wait to finish setting. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 47 • CHILD PROOF (To activate press buttons simultaneously. displayed and the handset is rendered inoperable (except for off functi- on). • PROGRAM MODE • THERMOSTATIC MODE (also deactivates Program Mode) • ECO MODE • MULTI-BURNER FEATURE • COUNTDOWN TIMER Element4 Gas Fireplaces EuropeanHome.com...
  • Page 48 Since it is a metal fireplace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction of these metals. The premium materials and build quality of your fireplace will keep these sounds to a minimum. To see an Element4 fireplace starting and running normally please visit the link below.
  • Page 49: Maintenance

    Remove the ROPE GASKET starting from one end down to the other end To see how to remove the glass from an Element4 fireplace please visit the link below. WWW.EUROPEANHOME.COM/RESOURCES/VIDEOS/ The ROPE GASKET will be removed for any remaining sides.
  • Page 50 Adjust the remaining glass panels left to right until there is no corner gap. Step 4. While ensuring that the glass panels are tight and square to each another, carefully install the remaining rope gaskets. PROPERLY PLACE ROPE GASKET(S) AND SEAL THE GLASS PANEL(S) BEFORE LIGHTING THE FIRE! Element4 Gas Fireplaces EuropeanHome.com...
  • Page 51: Burner

    The pilot has two distinct flames, one engulfing the thermocouple on its left, the other reaching across to the main burner. The area around the pilot should be inspected for cleanliness. Lint or foreign material must be removed with a brush or vacuum. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 52: Thermocouple

    MAINTENANCE THERMOCOUPLE MAINTENANCE The Element4 fireplaces have two thermocouples; one next to the pilot and one opposite the pilot side of the main burner. The completeness and operation of both must be checked. A qualified installer must confirm that both thermocouples are in place and not damaged.
  • Page 53: Warranty

    European Home is a division of Europa Ja, Inc. PRODUCT INSTALLATION RECORD Installer: Please complete this form. Customer: Please retain this information. Model Modore 95 MKII Bidore 95 MKII Trisore 95 MKII (check one) Purchased From Date of Purchase...
  • Page 54: Massachusetts Certification

    Gas Fitters has issued approval number G3-0116-219  for this appliance. The following must be observed when installing the Element4 fireplaces within the Commonwealth of Massachusetts: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole...
  • Page 55: Troubleshooting Flowchart

    Micro switch not Replace gas valve. operating properly. ON/OFF switch is in If equipped, set switch to ON ( | ) position. the OFF (O) position. 2nd thermocouple Confirm integrity of 2nd thermocouple and not connected connection. (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 56 Check that ceramic seen) shield or ignition wire is not defective. Short between interrupter block and TC- Check connection to interrupter block. cable. Sparking stops after pilot is lit. Electronic measuring amplifier defective. Replace the receiver. (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 57 Turn the control knob to “ON” position, a Manual knob is in the “MAN” position. positive latch is required. Main burner is lit. Confirm correct gas pressure. Increase pilot Pilot flame is too low. flame if necessary. (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 58 Test the batteries, replace if necessary. Receiver batteries low. Quality 1.5V AA alkaline recommended. Magnet unit drops Ensure magnet unit is operating while motor turns. Test the receiver output to the magnet unit. normally. Receiver makes 3 beeps. (continued) Element4 Gas Fireplaces EuropeanHome.com...
  • Page 59 Check venting for complete integrity. Reduce the primary air opening until flames have blue Too much primary air. base and yellow upper two-thirds. Flames are stable but too small and blue. NORMAL OPERATION Element4 Gas Fireplaces EuropeanHome.com...
  • Page 60 APPENDIX TWO Remote/Receiver Combinations Element4 Gas Fireplaces EuropeanHome.com...
  • Page 61 Increase the flame height: Press and hold the UP button. DOWN • Decrease the flame height: Press and hold the DOWN button. • For fine adjustment tap the UP or DOWN button as necessary. • Turn fireplace OFF: Press the ON/OFF button. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 62 Frequent ON and OFF cycles will limit life expectancy of the valve and will increase battery consumption. The fireplace should be powered by the AC adapter for improved reliability and customer satisfaction. Element4 Gas Fireplaces EuropeanHome.com...
  • Page 63 TROUbLEShOOTING Appendix 2 vENTING nstaLLing the onfiguration ressures orizontaL erMinations erticaL erMinations estrictors KEY INSTALLATION POINTS 6 Learances LISTING LAbEL 8 WALL ACCESS dOOR 34 WALL SWITCh Appendix 3 WARRANTY 3 MAINTENANCE urner iLot herMocoupLes MANTELS 16 Element4 Gas Fireplaces EuropeanHome.com...
  • Page 64 Imported and distributed in North America by: EUROPEAN HOME a division of Europa Ja, Inc. 30 Log Bridge Road Building 300 - Suite 303 Middleton, MA 01949 www.europeanhome.com IGE45II-180516 Element4 Gas Fireplaces EuropeanHome.com...

This manual is also suitable for:

Trisore 95 mkiiBidore 95 mkiiTrisore 140 mkiiModore 140 mkiiSky t mkiiSky mkii ... Show all