Clearances; Locating The Fireplace; Placing The Fireplace - Element4 Modore 185 GSB Installation, Operation And Owner's Manual

Direct vent gas fireplaces
Table of Contents

Advertisement

These are NOT zero-clearance fireplaces. All clearances to
combustible AND non-combustible materials MUST be maintained
as described in this manual.

LOCATING THE FIREPLACE

When selecting a location for the fireplace:
• Ensure that all minimum clearances to combustible AND
non-combustible materials are met.
• Provide adequate clearances for servicing.
• Consider venting dimensions (rise, run and number of
elbows, etc.) when selecting the location for your fireplace.
• Locate the appliance out of traffic and away from furniture
and draperies.
• Keep the location free of electrical, plumbing or other
heating/air conditioning ducting.

PLACING THE FIREPLACE

The base upon which the appliance rests must be sturdy, level
and built to safely support at least 500 pounds (230 kilograms).
The base may be the floor or a purpose-built raised platform, e.g.
wood, metal. When placed on a platform, a minimum 24 in
2
mm
) opening must be cut through the platform top. The lineset
can be routed through this opening. Room air must be allowed
to flow through the convection air inlets and then through this
platform opening. A linear cutout shape (Figure
best.
Do not place anything between the bottom of the firebox and
the bottom of the feet.
Figure 12
ENSURE THAT THE LINESET (WHICH INCLUDES THE GAS
ENSURE THAT THE LINESET (WHICH INCLUDES THE GAS
VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT
VALVE, ELECTRICAL WIRING, AND GAS LINES) DOES NOT
IMPEDE THE FULL OPERATION OF THE RELIEF DOORS. IT IS
IMPEDE THE FULL OPERATION OF THE RELIEF DOORS. IT IS
YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE
YOUR RESPONSIBILITY TO ENSURE THE SAFETY OF THESE
CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION
CRITICAL COMPONENTS THROUGHOUT THE INSTALLATION
PROCESS. REMOVE AND DISPOSE OF ALL WRAPS AND TIES.
PROCESS. REMOVE AND DISPOSE OF ALL WRAPS AND TIES.
Element4 Gas Fireplaces Rev #08042022

CLEARANCES

MINIMUM CLEARANCE TO COMBUSTIBLES
• The appliance is approved with a minimum clearance to
combustible materials of 26" (660 mm) to the top, 11" (280
mm) on all sides and 4" (100
or framing used closer than this dimension must be non-
combustible (e.g. metal).
• The minimum distance from the bottom of the appliance to
the room ceiling is 72" (1830 mm).
• When installing the venting, the following clearances to
combustible materials MUST be maintained:
a. 3"/76
b. 1"/25
• Do not block or restrict the Air Inlet or the Air Outlet
The minimum clearances (air spaces) to combustible materials
must be maintained. It is of the greatest importance that the
fireplace and vent system be installed only in accordance with
these instructions.
2
(610
Clearance to combustibles summary:
12
) will perform
The Floor dimension (above) is measured from the bottom of the
firebox. When the adjustable feet are in their lowest position the
required clearance to the floor is maintained.
15
mm)
above any horizontal venting
mm
to venting sides or below any horizontal
mm
venting
Front: 11" (280 mm)
Back:
11" (280 mm)
Sides:
11" (280 mm)
Top:
26" (660 mm)
Floor:
4" (100 mm)
to the bottom. Any spacer