Download Print this page
BEA CRYSTAL User Manual
BEA CRYSTAL User Manual

BEA CRYSTAL User Manual

Active infrared presence detector

Advertisement

Quick Links

PRODUCT
The Crystal Active Infrared presence detector (PN: 10CRYSTALPRE) is ideal for threshold safety and sidelite protection for
sliding doors, as well as threshold protection on the approach side of a swinging or bi-folding door. It is universally
DESCRIPTION
compatible with any automatic door control, and is quick and easy to install. The Crystal technology utilizes multiplexing,
which assures that it is constantly scanning the background looking for any changes. Therefore, if the change in
background remains constant for a set time (adjustable 1 minute or 10 minutes), the sensor learns it and allows your door
to return to normal operation.
NOTE: The Crystal should not be used as a motion detector. The Crystal's detection pattern does not meet
TECHNICAL
TECHNICAL SPECIFICATIONS
SPECIFICATIONS
Installation Height:
Detection Zone:
Mounting Angle:
Power Supply:
Consumption:
Output - Contact Ratings:
Max. voltage
Max. current
Max. switching power
Frequency:
Response Time:
Relay hold time:
Auto Learn Time
Temperature range:
Dimensions:
Weight:
Material:
Length of Cable:
COMPONENT ID
SAFETY
• Shut off all power going to the header before attempting any wiring procedures.
PRECAUTIONS
• Maintain a clean & safe environment when working in public areas.
• Constantly be aware of pedestrian traffic around the door area.
• Always stop pedestrian traffic through the doorway when performing testing that may result in unexpected reactions by
the door.
• Always check placement of all wiring and components before powering up to insure that moving door parts will not
catch any wires and cause damage to equipment.
• Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
75.0069 V4 [Rev 8/28/2002]
USERS GUIDE
PRESENCE SENSOR
the minimum motion pattern requirements as stated by ANSI A156.10.
Supply
Cable
Cover
DIP
Switches
Connector
Learn time
CRYSTAL
7' to 10'
Wide pattern: 6'
Narrow pattern: 3'
Depth: 4"
from 3° to 21°
12 to 30 V DC ± 10%
12 to 24 V AC ± 10%
< 1 W (VA)
Dry Contacts
60 V DC / 125 V AC
1 A (resistive)
30 W (DC) / 60 VA (AC)
50 to 60 Hz
< 50ms
1.5 seconds (fixed)
1 or 10 minutes
-30° to +131° F
10" L x 2" H x 1.5" D
7 oz.
Black ABS and polycarbonate
6'
LED
Angle
adjustment
Receiving
lens
Emitting
lens
Page 1 of 6

Advertisement

loading
Need help?

Need help?

Do you have a question about the CRYSTAL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BEA CRYSTAL

  • Page 1 It is universally DESCRIPTION compatible with any automatic door control, and is quick and easy to install. The Crystal technology utilizes multiplexing, which assures that it is constantly scanning the background looking for any changes. Therefore, if the change in background remains constant for a set time (adjustable 1 minute or 10 minutes), the sensor learns it and allows your door to return to normal operation.
  • Page 2: Mechanical Installation

    ACTIVATE and COMMON terminals of the door control (see below). b) If the Crystal is installed to protect the sidelites of a sliding door, it could be connected to the SAFETY and COMMON terminals of the door control, or could also be wired to open the activation circuit when in detection, but only when the door is fully closed;...
  • Page 3 See the diagrams below for details on wiring a Crystal to a door without safety. 1. If the Crystal is used for sidelite safety on a sliding door, it must be wired (NC & COM) in series with the motion detector.
  • Page 4 10 minutes = POWERING THE Upon supplying power to the Crystal (12 to 30 V DC ± 10% or 12 to 24 V AC + 10%), the following should be observed: SENSOR The Red LED on the front of the sensor will illuminate immediately upon powering the sensor Insure that the field of detection remains uninterrupted while the Red LED is on.
  • Page 5 NOTE: The distance of detection from the door will increase as the mounting height of the Crystal is increased. It will also decrease as the mounting height of the Crystal is decreased. ALWAYS be sure to walk-test the door upon completion of all sensor adjustments, to insure compliance with applicable safety standards (i.e.
  • Page 6 ACCESSORIES PN: 10URC PN: 10CCA Universal Rain Cover Crystal Ceiling Adaptor COMPANY If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc. CONTACT for further assistance during Eastern Standard Time at 1-800-523-2462 from 8am - 5pm.

This manual is also suitable for:

10crystalpre