Opening & safety sensor
for automatic sliding doors (9 pages)
Summary of Contents for BEA CONDOR ID
Page 1
CONDOR ID QUICK GUIDE RFID GATE SENSOR 12-24V GREEN POWER- BROWN SUPPLY WHITE START- YELLOW SIGNAL GREY STOP- PINK SIGNAL VIOLET BLACK 45° 30° 15° START STOP > 2.8 m < 2.8 m RED-GREEN RED-GREEN At the end of the installation or...
CONDOR ID USER’S GUIDE RFID GATE SENSOR DESCRIPTION Fixing screw Adjustment screw for radar tilt angle Infrared lenses Radar antenna LED-SIGNAL GREEN LED RED LED RED-GREEN LED START-SIGNAL STOP-SIGNAL SETUP LED FLASHES LED FLASHES LED OFF QUICKLY SLOWLY INSTALLATION TIPS...
Page 3
DETECTION FIELD The Spotfinder is necessary to position the detection field correctly. The CONDOR ID should be positioned by using the Spotfinder so that the START-line is at the desired distance from the sensor. Therefore the Spotfinder should be put on the floor and turned towards the sensor.
REMOTE CONTROL PRESETTINGS Installation height <2.8m >2.8m Max. duration of presence detection IR-Immunity Detection field size Rejection mode Holdtime STOP-Relay RFID-mode Relay configuration At the end of the installation or after changing the adjustment of the sensor,it is MANDATORY to introduce the preset value in function of the installation height by remote control.
REMOTE CONTROL How to adjust one or more parameters? Select parameter Set value How to check one or more values? Select parameter X value GREEN The number of green flashes indicates the value of the chosen parameter. SETTINGS OVERVIEW RFID-mode Holdtime STOP-Relay radar + IR seperately 0 ms...
TROUBLESHOOTING SYMPTOMS POSSIBLE CAUSES CORRECTIVE ACTION During setup the LED The power supply is too weak. Make sure the power supply is continues to flash stable. quickly red-green. RED-GREEN High intensity light (discharge During setup the LED Change the position of the lamps. lamps) disturbs the sensor.