Option List of Controllers
1. Option List of Controllers
1.1
Operation Control System Optional Accessories
For VRV indoor unit use
No.
Item
Wireless H/P
Remote
1
controller
Wired
Navigation remote controller
2
(Wired remote controller)
Wired remote controller with
3
weekly schedule timer
Simplified remote
4
controller (Exposed type)
Remote controller for hotel
5
use (Concealed type)
6
Adaptor for wiring
Wiring adaptor for
7-1
electrical appendices (1)
Wiring adaptor for
7-2
electrical appendices (2)
Remote sensor
8
(for indoor temperature)
Installation box for adaptor
9
printed circuit board
External control adaptor
10
for outdoor unit
11
Adaptor for multi tenant
Drawing No.
C: 3D084501B
No.
Item
Wireless H/P
Remote
1
controller
Wired
Navigation remote controller
2
(Wired remote controller)
Wired remote controller with
3
weekly schedule timer
Simplified remote
4
controller (Exposed type)
Remote controller for hotel
5
use (Concealed type)
6
Adaptor for wiring
Wiring adaptor for
7-1
electrical appendices (1)
Wiring adaptor for
7-2
electrical appendices (2)
Remote sensor
8
(for indoor temperature)
Installation box for adaptor
9
printed circuit board
External control adaptor
10
for outdoor unit
11
Adaptor for multi tenant
External control adaptor
12
for cooling / heating
Remote control adaptor
13
with key
Drawing No.
Notes:
1. Installation box (No.9) is necessary for each adaptor marked .
2. Up to 2 adaptors can be fixed for each installation box.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
5. Installation box (No. 9) is necessary for second adaptor.
6. Installation box (No. 9) is necessary for each adaptor.
7. Individual airflow direction, auto airflow rate and sensing sensor control can be set only via wired remote controller
BRC1E62. Cannot be set via other remote controllers. Available functions depend on the type of indoor unit.
8. Since the control panel is equipped as standard, use the option for 2 remote control system.
9. When using BRC1E62, be sure to remove the control panel and since BRC1E62 cannot be stored inside the
indoor unit, please place it separately.
10.Remove the group control adaptor which is a standard equipment before mounting KRP6A1 and DTA104A62.
KRP6A1 and DTA104A62 cannot be mounted to the same indoor unit at the same time.
526
FXFQ-S
FXFQ-LU
BRC7F634F
—
BRC1D61
KRP1C63
KRP2A62
KRP4AA53
KRCS01-4B
Note 2, 3
KRP1H98
DTA104A62
DTA114A61
C: 3D081321A
FXMQ-P
FXMQ-MA
BRC4C65
BRC4C62
BRC2C51
BRC3A61
KRP1C64
KRP1B61
KRP2A61
KRP2A61
KRP4AA51
KRP4AA51
KRCS01-4B
Note 2, 3
—
KRP4A96
DTA104A61
DTA104A61
DTA114A61
—
C: 3D060455D
C: 3D034600K
Type
FXZQ-M
FXUQ-A
BRC7E530W
BRC7CB58
BRC1C62
Note 7
BRC1E62
—
—
—
KRP1BA57
—
KRP2A62
—
KRP4AA53
KRP4AA53
KRCS01-1B
KRCS01-4B
Note 4, 6
KRP1BA97
KRP1BA101
DTA104A62
—
—
—
C: 3D023974R
C: 3D080116A
Type
FXHQ-MA
FXAQ-P
BRC7EA63W
BRC7EA618
BRC1C62
Note 7
BRC1E62
BRC1D61
—
—
KRP1BA54
KRP2A62
KRP2A61
KRP4AA52
KRP4AA51
KRCS01-1B
Note 3
Note 2, 3
KRP1CA93
KRP4AA93
DTA104A62
DTA104A61
DTA114A61
—
—
—
C: 3D034600K
C: 3D023974R
FXCQ-M
FXKQ-MA
BRC7C62
BRC4C61
BRC1D61
KRP1B61
KRP1B61
KRP2A61
KRP2A61
KRP4AA51
KRP4AA51
KRCS01-1B
Note 2, 3
—
KRP1B96
DTA104A61
DTA104A61
—
—
C: 3D034600K
C: 3D034600K
FXLQ-MA
FXNQ-MA
BRC4C62
BRC2C51
BRC3A61
—
KRP1B61
KRP2A61
KRP4AA51
—
DTA104A61
—
C: 4D034581A
Option of Control
EDMT331529A
FXDQ-PB
FXDQ-NB
BRC4C65
BRC2C51
BRC3A61
KRP1B56
KRP2A53
KRP4A54
Note 4, 6
KRP1BA101
DTA104A53
—
C: 4D060939C
FXVQ-N
—
Note 8
BRC1C62
Note 9
BRC1E62
—
—
—
KRP1C67
KRP2A62
—
—
Note 10
DTA104A62
—
Note 10
KRP6A1
KRCB37-1
C: 3D085669E