Altronix eFlowNA8 Series distribute and switch power to access control systems and accessories. They convert a
120VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs. These power
outputs can be converted to dry form "C" contacts. Outputs are activated by an open collector sink or normally
open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units
will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic
Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables
Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect
feature is individually selectable for any or all of the eight (8) outputs.
eFlowNA8 Series Configuration Reference Chart:
Altronix
Model
Number
eFlow4NA8
3.5A
eFlow6NA8
3.5A
eFlow102NA8
3.5A
eFlow104NA8
4.5A
*eFlow4NA8 only: This unit is classified as Power-Limited stand alone power supply with stand-by battery and it
is suitable to power: sensors, electro-mechanical devices (e.g. electric door strikes).
*eFlow6NA8, eFlow102NA8, and eFlow104NA8: The DC output for these power supplies are not power-limited.
If a power-limited output is required in the end-product application, the DC output from the power supply must be
connected to a separately Listed control unit or accessory board that provides power-limited outputs. The product(s)
providing the power-limited output(s) must be listed as appropriate for the particular end-product application (access
control), and wired in accordance with the products installation instructions. Class 1 wiring methods, separation of
circuits, and proper fire-rated enclosures all must be considered when connecting the DC output of the power supply
to the end-product devices. The auxiliary outputs of these units are power-limited.
UL Listings for US Installations:
UL 294* - UL Listed for Access Control System Units.
*Access Control Performance Levels:
Destructive Attack - I, Endurance Test - IV, Line Security - I, Stand-by Power - II, III, IV
UL Listings for Canadian Installations:
ULC-S319-05 - Electronic Access Control Systems. Class I Equipment.
CSA C22.2 No.205 - Signal Equipment.
Altronix Corp.
140 58th St. Brooklyn, NY
California State Fire Marshal
European Conformity
- 2 -
Nominal DC Output
Voltage Options
[DC]
5A/
7.5A/
10.1-
250V
32V
13.2
5A/
10A/
10.0-
250V
32V
13.2
5A/
15A/
10.03-
250V
32V
13.2
6.3A/
15A/
–
250V
32V
Overview:
[AUX]
12VDC
20.28-
10.05-
20.2-
26.4
13.2
26.4
20.19-
10.03-
20.19-
26.4
13.2
26.4
10.03-
–
–
13.2
20.17-
20.17-
–
26.4
26.4
24VDC
3.3A
3.6A
8
5.3A
5.6A
8
9.3A
–
8
–
9.6A
8
eFlowNA8 Series Installation Guide
10A/
3.5A/
2.5A
250V
250V
10A/
3.5A/
2.5A
250V
250V
10A/
3.5A/
2.5A
250V
250V
10A/
3.5A/
2.5A
250V
250V
Need help?
Do you have a question about the eFlowNA8 Series and is the answer not in the manual?
Questions and answers