The value must be within the prescribed ones.
VALVES
INTAKE
EXHAUST
If not, remove the closing shim (2), as described in paragraph
suitable height to obtain the prescribed clearance.
Note
Opening rocker arm shims measuring 1.80 to 3.45 are available as spare parts: the size is punched on the shim.
Checking the opening clearance
Using a feeler gauge, check the clearance between the opening rocker arm (A) and the lowest point of the
CLOSING CLEARANCE (mm)
0.05 ÷ 0.10
0.05 ÷ 0.10
"Removing the
valves", and replace it with one of