Download Print this page

Specifications; Water Consumption - Champion Model 106 PW Specifications

84" two tank with 22" prewash high temperature rack conveyor dishwashing machine

Advertisement

Model 106 PW
84" Two Tank with 22" Prewash
High-Temperature
Rack Conveyor Dishwashing Machine
Volume crated:
Shipping weight crated:
Utilities
1 Electrical
a Machine connection (see Table A)
b Booster connection (see Table B)
2 Hot Water
3/4" NPT 180°F/82°C min. hot water
connection. (Machine without booster.)
3/4" NPT 140°F/60°C min. hot water
connection. (40°F/22°C rise booster)
3/4" NPT 110°F/49°C min. hot water
connection. (70°F/39°C rise booster)
Flow pressure 20-22 psi.
3 Drain
1-1/2" NPT machine connection.
Maximum flow 15 gpm.
4 Steam
a 3/4" NPT machine connection.
Flow pressure 15-30 PSI. (Steam coil)
b 3/4" NPT machine connection.
Flow pressure 15-30 PSI.
(Steam injector)
5 Condensate
(no back pressure)
1/2" NPT machine return to boiler
6 Vents
a Load end: 200 CFM @ 1/4" S.P.
b Unload end: 400 CFM @ 1/4" S.P.
(With blower-dryer increase room
ventilation by 600 CFM.)
Table a - Machine connecTion
Machine only
Minimum
Supply Ckt.
Elec.
Rated
Conductor
Specs.
Amps
Ampacity
208/60/1
171
225
240/60/1
150
200
208/60/3
95
125
240/60/3
83
100
480/60/3
41
50
575/60/3
32
40
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
175 cu. ft.
1,000 lbs.
Table b - boosTer connecTion
40°F/22°C Rise – 15kW
Electric built-in booster (booster only)
Elec.
Specs.
208/60/3
240/60/3
480/60/3
575/60/3
70°F/39°C Rise – 24kW
Electric built-in booster (booster only)
Elec.
Specs.
208/60/3
240/60/3
480/60/3
575/60/3
Machine and steam built-in booster
Elec.
Specs.
208/60/1
240/60/1
208/60/3
Maximum
Overcurrent
240/60/3
Protective
Device
480/60/3
225
200
125
100
Warning:
50
all the applicable plumbing, sanitary, safety codes and the National Electrical Code.
Note:
40
Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied (by others)
in common water supply line at service connection.
Plumbing Notes:
water pressure regulating valves (PRVs) may be needed. (Water PRV is standard on machines with booster.)
The PRVs can either be purchased from Champion or obtained locally.
Venting Notes:
Minimum
Maximum
Supply Ckt.
Overcurrent
Rated
Conductor
Protective
Amps
Ampacity
Device
42
50
36
45
18
25
15
20
Minimum
Maximum
Supply Ckt.
Overcurrent
Rated
Conductor
Protective
Amps
Ampacity
Device
67
80
58
70
29
35
24
30
Minimum
Maximum
Supply Ckt.
Overcurrent
Rated
Conductor
Protective
Amps
Ampacity
Device
41
50
36
50
20
25
17
25
9
15
Plumbing and electrical connections should be made by qualified personnel who will observe
Because of the variation in house-supplied steam and water pressures, steam and
Fabricated duct size: 3-7/8" x 15-7/8" (Outside dimensions)

sPeciFicaTions

Capacity
Racks per hr. (NSF rated)
Wash tank (US gal.)
Conveyor speed (ft/min.)
50
Motor Horsepower
45
Drive
25
Prewash
20
Wash 3
Rinse 3

Water Consumption

US Gal. per hr. (max. use)
US Gal. per rack
Heating
80
Tank Heat, electric (kW)
70
Tank heat, steam
35
(lbs/hr. required at
15 PSI flow pressure)
30
Electric booster (built-in)
(kW supplied for 40°F rise)
Electric booster
(kW supplied for 70°F rise)
Steam booster (lbs./hr.
required for 40°F rise)
Steam booster (lbs./hr.
50
required for 70°F rise)
Venting
50
Load end (minimum CFM)
25
Unload end (minimum CFM)
25
Standard 20" x 20"
15
rack complement
Peg
Flat
Dimensions shown in inches
356
21
9.9
1/6
1
131
.37
25
75
15
24
75
120
200
400
2
1

Advertisement

loading

This manual is also suitable for:

106 pw