Technical Data - oventrop Regusol Installation And Operating Instructions For The Specialised Installer

Dn 32 with universal insulation
Table of Contents

Advertisement

Available languages

Available languages

4 Technical data

4.1 Performance data
Nominal size:
Max. operating temperature t
Max. operating pressure p
Safety valve:
Opening pressure
check valve:
Mechanical flow
measuring device:
K
-value:
vs
Distance between
pipe centres:
Connections:
The technical data of the solar pump is detailed in the
separate operating instructions enclosed with the
pump.
Fluid: Non-aggressive fluids (e.g. water and suitable
water and glycol mixtures according to VDI 2035). Not
suitable for steam, oily and aggressive fluids.
!
DANGER
Suitable measures (e.g. safety valves) have to
be taken to ensure that the maximum operating
pressures and max. operating temperatures are
not exceeded.
4.2 Materials
Valves and fittings
Insulation
Wall mounting device
Seals
Scale tube
Handles
Flanged pipe
Pump body
DN 32
:
120 °C
s
:
6 / 10 bar (PN10)
s
6 / 10 bar
20 mbar
10-40 l/min
5.5
125 mm
G2 male thread
flat sealing
Brass
EPP
PA6.6
EPDM
PSU
PA6.6
Copper
Cast iron
4.3 Dimensions/Connection sizes
Illustr. 4.1 Solar station "Regusol SH-180" DN32
4.4 Pump characteristic line