1. General information
1.1 Information regarding operating
instructions
These operating instructions help the trades-
man to install, put into operation and service
the "Floorbox".
Before installation, the operating instructions
are to be read in their entirety
1.2 Symbol explanation
Guidelines for the safety of persons and the in-
stallation itself are displayed by symbols. These
guidelines must be observed in order to avoid
accidents, damage to property and malfunctions.
DANGER
Imminent danger to life and limb
Attention
Possible danger to product, instal-
lation or environment
Note
Useful information and notes
1.3 Copyright
The installation and operating instructions as
well as the included texts, drawings, images and
other illustrations are copyrighted.
2. Safety notes
The "Floorbox" has to be installed by an autho-
rised specialist tradesman with due consideration
of valid standards and rules. We do not accept
liability for damages and malfunctions caused
by nonobservance of theses instructions.
WARNING Risk of scalding
Hot escaping fluids may lead to bad scalds.
Hot pipes may also lead to scalds
3. Technical data
3.1 Dimensions
See illustr. 3.1, 3.2 and 5.1
8
Installation and operating instructions
3.2 Performance data
Max. working pressure:
Max. differential pressure:
Max. working temperature:
k
value: 6.6 m
3
/h (the k
vs
regulating and commissioning valve "Hycocon
VTZ" must also be taken into account, see point
"6.1 Regulation" and "6.2 Calculation example").
Illustr. 3.1: Dimensions lateral connection
Illustr. 3.2: Dimensions lower connection
"Floorbox"
10 bar
1 bar
100°C
value of the double
vs
Frame: 432
Dimensions: 400
100
Frame: 432
Dimensions: 400
105
110
70