8. 3 OPERATING PROCEDURES

Once the remote fill system is set up, follow the procedures
described in chapter 3.1 DESCRIPTION OF CONTROLS to
activate the Autofill system.
IMPORTANT
The device is designed so as no refilling occurs in case
either the clip probe is not properly installed or the bowl
not properly fitted.
If the clip probe is properly installed and the bowl properly fitted
in their position, the remote fill system starts to operate and
feed the bowl through the hole in the rear wall. As soon as the
product level reaches the lowest tip of the probe, the priming
automatically stops.
As soon as the probe tip immersed in the product gets
uncovered (because of dispensed product), the solenoid valve
inside the rear wall automatically opens and fresh beverage
flows into the bowl until the probe tip gets covered again.
The solenoid valve opening occurs with about 10 seconds
delay to avoid that the irregular waving of product surface,
occasionally discovering probe tip, may be understood as level
dropping "cause of dispensing".
A sold-out warning light along with a buzzer (visual and
acoustic sold-out alarms) are located respectively on and
inside the rear cover. They can run only if an applicable Sold-
out switch is connected to the terminal block (see figure 19).

8. 3. 1 DESCRIPTION OF CONTROLS

Each Autofill Device is equipped with a three position switch
located on the rear wall.
Its functions are as follows:
I position
: Autofill Device is turned ON, provided that the
power switch of the unit is set to I.
0 position
: Autofill Device is turned OFF.
II position
: Autofill Device may be manually activated
(momentary position). By keeping manually
pushed the switch in this II position, it is
possible to manually activate the refilling by-
passing all the controls (both the clip probe and
the sold-out switches). This feature is useful for
priming in the first time operation or whenever a
sold-out occurs. The same feature is also
helpful for cleaning and sanitizing procedures.
To operate the Autofill Device:
1 - Set the power switch of the unit to I position.
2 - If it is first time operation: manually energize the Autofill
Device, by keeping pushed the Autofill Switch in position II,
until the priming is completed. Set the Autofill switch to I
position.
If this is not first time operation: set Autofill switch to I
position.
3 - Set the unit mixer/refrigeration switch of the bowl to
II position.
Note: when Autofill switch is set to position 0, the unit performs
as a standard unit not equipped with Autofill Device.

8. 3. 2 OPERATIONAL HELPFUL HINTS

1 - When the remote fill system is equipped with Sold-out
switches if a product sold-out occurs the Autofill Device
12
automatically stops and acoustic and visual alarms are
activated. Once product is restored, by keeping manually
pushed the Autofill switch (located in the rear wall) in II
position, it is possible to manually reactivate the remote fill
system as already told in 3.1.
2 - The 1.25 Amps Fuse located near the terminal block has
the purpose to protect the Autofill Devices from short
circuits or overloads on #1 and #2 poles.
3 - After cleaning and sanitizing procedures carefully dry the
bowl and the clip probe to avoid that the water present on
the bowl may be understood as level reaching the probe
and "causing of stopping of the refill".

8. 3. 3 IN-PLACE SANITIZATION

T h e I n - P l a ce S a n i t i z a t i o n o f t h e A u t o f i l l s y s t e m i s
recommended to guarantee the best product taste and the
highest unit efficiency. This section is a procedural guideline
only and is subject to the requirements of the local Health
Authorities.
Prior to perform the In-Place Sanitization the machine must be
emptied of product. To do this proceed as follows:
-
set the Autofill switch to 0 position.
-
set the unit power switch to I position
-
set the unit mixer/refrigeration switch to I position (Soft
Drink mode)
-
place a pail under each faucet and drain all product from
bowls
-
set all control switches to 0 position
1 - Use a clean tank for each of the following:
a -Cleaning Tank - fill with warm (45-60 °C / 120 - 140 °F)
potable water.
b -Sanitizing Tank - fill with sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of sodium
hypoclorite diluted with half a gallon of water) according
to your local Health Codes and manufacturer's
specifications.
2 - Repeat the following procedure on each of the unit bowls:
a -Disconnect the beverage source and in place of it
connect the Cleaning Tank to the remote fill system line.
b -Set the unit Power Switch to position I. Manually
energize the Autofill Device, by keeping pushed the
Autofill Switch (located on the rear cover of each bowl)
in position II, until the cleaning water flows free from any
beverage residue.
Set the unit Power Switch to position 0 and drain all the
liquid from the bowl.
c -Disconnect the Cleaning Tank and in place of it connect
the Sanitizing Tank to the remote fill system line.
d -Set the unit Power Switch to position I. Manually
energize the Autofill Device, by keeping pushed the
Autofill Switch (located on the rear cover of each bowl)
in position II, until sanitizing solution only outflows.
Flush at least a quarter of a gallon of sanitizing solution
to make sure that all the system has been filled with it.
Set the unit Power Switch to position 0 and drain from
the bowl all the sanitizing solution.
e -Disconnect the Sanitizing Tank and in place of it
connect the Beverage source to the remote fill system
line.
f -Set the unit Power Switch to position I. Manually
energize the Autofill Device, by keeping pushed the
Ugolini spa