PROBLEM
PROBABLE CAUSE
1
A
Dispensing unit unplugged.
Light display
B
No power from Terminal Block.
not lit.
C
Defective Bulb.
D
Defective Ballast.
E
Loose Bulb in socket.
2
A
Water supply OFF.
No water when
B
Clogged inlet screen (Water Inlet Valve).
Rinse Switch is
C
Inoperative Water Inlet Valve.
ON.
D
Loose electrical connection.
3
A
No product in Canister.
No product
B
Auger not working.
when Dispense
C
Damaged, loose, or missing Agitator Gear.
Button is
D
Inoperative Auger Motor or Relay.
pressed
E
Canister outlet clogged.
F
Faulty Coupling.
4
A
Leaking Water Inlet Valve.
Water does not
shut off.
Water keeps
B
Inoperative Dispense Switch.
dispensing.
C
Inoperative Rinse Switch.
D
Clogged/stuck Water Dispense Valve.
5
A
Water Inlet Valve malfunction.
No water is
B
Dual Probe malfunction.
going into tank
C
Dual Probe Liquid Level Controller malfunction. Check Controller. Replace if necessary.
at all.
6
A
Dual Probe malfunction.
Water will not
B
Solenoid (Water Inlet Valve) malfunction.
stop flowing into
C
Dual Probe Liquid Level Controller malfunction. Check Controller. Replace if necessary.
water tank.
7
A
Heater Switch is OFF.
Water is not
B
Thermostat is OFF.
heating up in
C
Loose connection on Thermostat.
water tank.
D
Hi-Limit Temperature Switch is defective
E
Heater is burned out or defective.

TROUBLESHOOTING GUIDE

DISCONNECT POWER CORDS
REMEDY
Reconnect dispensing unit.
Check the Terminal Block for loose wire.
Replace Bulb.
Replace Ballast.
Make sure bulb is seated properly in socket.
Turn water ON.
Disconnect water line and clean inlet screen.
Check connection, if needed replace Valve.
Check all electrical connections.
Add product.
Engage Hopper/Nut to Motor Gear.
Replace Agitator Gear.
Check connections of Motor, Relay and/or Switch, if
needed replace components.
Clean Hopper.
Replace damaged Coupling components.
Clean/check Water Inlet Valve fittings. Replace Water
Inlet Valve
if needed.
Check Switch connections. Replace Dispense Switch if
needed.
Check Rinse Switch connections.
Replace Rinse Switch if inoperative.
Clean or unclog Water Dispense Valve.
Replace Dispense Valve if inoperative.
Check Solenoid. Replace if necessary.
Check Probe. Replace if necessary.
Check Probe. Replace if necessary.
Check Solenoid. Replace if necessary.
Turn Heater Switch ON.
Turn Thermostat ON.
Make sure all wires and terminals on Thermostat are
tight.
Replace the Hi-limit switch.
Replace the Heater.