Hot Installation - Compaq StorageWorks FCA2257C Installation Manual

Cpci host bus adapter for sun solaris
Table of Contents

Advertisement

Hot Installation

Perform the following steps to install the adapter without shutting down the system
(hot installation).
To hot install the cPCI adapter:
1. Log on to the system as a superuser.
2. At the system prompt (#), enter the following command to find an available slot
for the adapter:
cfgadm
A list of the system's processors, memory, and I/O slots appears, as shown in the
following example. In this example, the shaded rows indicate that CPCI slots 0, 1,
3, and 4 are available.
Ap_Id
N0.IB6
N0.IB8
N0.SB0
N0.SB2
c0
pcisch0:sg6slot2
pcisch0:sg6slot3
pcisc1:sg6slot0
pcisch2:sg6slot4
pcisch2:sg6slot5
pcisch3:sg6slot1
3. Check the indicator lights next to the available slots (in some systems, the lights
are above the slots). The top two lights should be off; the bottom light should be
amber. This is another way to verify an available slot.
FCA2257C cPCI Host Bus Adapter for Sun Solaris Installation Guide
Type
Receptacle
CPCI_I/O_bo
connected
unknown
empty
CPU_Board
connected
CPU_Board
connected
scsi-bus
connected
stpcipci/fhs
connected
unknown
empty
unknown
empty
unknown
empty
unknown
connected
unknown
empty
Installing the Adapters
Occupant
Condition
configured
ok
unconfigured
unknown
configured
ok
configured
ok
configured
unknown
configured
ok
unconfigured
unknown
unconfigured
unknown
unconfigured
unknown
unconfigured
unknown
unconfigured
unknown
2–3

Advertisement

Table of Contents
loading

Table of Contents