4.0 DIP Switch Settings

Use the DIP switch settings in Sections 4.1 through 4.4
for the DX4020 network communication.
4.1
GV2 Series, G Series, and 9000
Series Control Panels
The GV2 Series consists of the following control
panels:
D9412GV2
D7412GV2
D7212GV2
The G Series consists of the following control panels:
D9412G
D7412G
D7212G
The 9000 Series consists of the following control
panels:
D9412
D7212
D7212
D9112
For proper network communication
between the DX4020 and the control panel,
the D9412G, D7412G, D7212G, D9412,
D7412, D7212, and D9112 require
firmware revision 6.3 or later.
Use SDI Bus Address 80 (Figure 6) with the DX4020
and PC9000. Use SDI Bus Address 88 (Figure 7) with
the DX4020 and RPS, or for network communication.
Figure 6:
DIP Switch Setting for Address 80
1
=
1 2 3 4 5 6 7 8
1 - ON (down)
Bosch Security Systems, Inc. | 1/09 | F01U045288-05
Conettix DX4020 | Installation Guide | 4.0 DIP Switch Settings
=
2
2 - OFF (up)
Figure 7:
DIP Switch Setting for Address 88
1
=
1 2 3 4 5 6 7 8
1 - ON (down)
4.2
DS7240V2, DS7220V2, and Easy
Series V3+ (ICP-EZM2) Control
Panels
For proper network communication
between the DX4020 and the control panel:
The DS7240V2 and DS7220V2 require
-
firmware revision 2.xx or later.
The Easy Series (ICP-EZM2) control
-
panel requires firmware version 3.0 or
later, and the DX4020 requires firmware
version 2.23 or later.
For network communication, set the DIP switches on
the DX4020 to Address 134 (Figure 8) when using the
DS7240V2, DS7220V2, or Easy Series V3+ control
panels.
Figure 8:
DIP Switch Setting for Address 134
1
=
1 2 3 4 5 6 7 8
1 - ON (down)
=
2
2 - OFF (up)
=
2
2 - OFF (up)
7