6.5
Using Telnet to Complete
Configuration
Refer to Section 6.5.1 Using Windows 98 Telnet when
using Windows 98.
Refer to Section 6.5.2 Using Windows 2000/XP Telnet
beginning on page 15 when using Windows 2000/XP.
6.5.1
Using Windows 98 Telnet
1. At the Start Menu, select Start
DOS window.
2. At the Run dialog box, type telnet and press
[Enter] to start the telnet application.
3. Select Connect
Remote System...
The Connect window opens.
4. At the Host Name field, type the DX4020 IP
address assigned in the previous section.
In this example, the IP address is 172.17.10.70.
5. At the Port field, type 1 and leave the TermType
field at vt100.
Bosch Security Systems, Inc. | 1/09 | F01U045288-05
Conettix DX4020 | Installation Guide | 6.0 IP Address Programming
6. Click Connect and wait a few seconds for the
following failed message to appear.
Run to open a
7. Click OK to open the Telnet window again.
8. Repeat Step 3 in Section 6.4.2 Using the ARP
Command, on page 10.
9. This time, leave all but the Port field the same.
Type 9999 in the Port field.
10. Click Connect.
11. Press [Enter].
If you do not press [Enter] within 5 sec of
seeing the "Press Enter to go into Setup
Mode" message, the system disconnects
you and the following message appears.