The DelREMO-V2.0 supports following features and interfaces:-
4 nos. of 0 to 10 VDC analog inputs for sensor integration like irradiance, pyranometer, temperature etc.
4 nos. of 4 to 20 mA DC analog inputs for sensor integration like, wind speed, humidity temperature etc.
8 nos. of potential free digital inputs for alarm input or inverter power management.
2 nos. of isolated RS485 communication ports maximum up to 62 devices.
LCD interface for local configuration & data display.
LED indication for device function & troubleshooting.
USB host for FW up-gradation & data log download.
Supports micro Dual SIM card (2G only).
Isolated input Power supply.
Increased data point support
Send data to server using Ethernet, GSM/GPRS.
XML configuration for faster customization
Remote management through E management
Built in RTC.
Built in 32MB memory for local data storage & expandable up to 32GB by micor-sd card.
2.3

Technical Specifications

Table 2.1 Input DC supply
Input (DC Supply)
Operating Range
Ultimate capacity
Short Circuit Protection
Fig 2.4 Bottom view of DelREMO-V2.0
Fig 2.5 Top view of DelREMO-V2.0
18 ~ 24 VDC (24VDC nominal)
20 Watt (Nominal)
Yes
10