Download Print this page

JDS Uniphase HST-3000 Quick Card page 6

Hide thumbs Also See for HST-3000:

Advertisement

3
Tap right to select the RFC 2544 Settings. Make
sure that
Load Format -> Bit Rate
Auto Save Report -> Enable
Auto Restore Cfg* -> Disable
You can also enter the customer, location,
technician and any comments you have that you
wish to be stored on the final report.
4
Tap right to select the Test Selections. Make sure
that
Throughput -> Enable
Latency (RTD)* -> Enable
Packet Jitter * -> Enable
Frame Loss -> Enable
Back to Back -> Disable
Max Bandwidth -> this will change at each
location but should be the CIR for the circuit.
5
Tap right to select the Frame Length Tab. Make
sure that
The smallest possible Frame Length is selected
(this will be either 64, 68, 70, or 72 depending
on the settings). To do this go to Frame Length
1 and select the value.
Select 512 entry 4.
Select 1518 or 1522 (whichever one you are
allowed to select) in entry 7.
Make all the rest of the entries disabled
Please see picture for a correct sample setup.
6
Tap right to select the Throughput. Make sure
that
Accuracy -> To within 0.1 (Mbps)
Test Dur. -> 120 sec
Frame Loss Tol -> 0Mbps
Show Pass/Fail -> No
Zero in Method -> JDSU Enhanced